Rigidity evaluation of quartz-fiber splints compared with wire-composite splints.

نویسندگان

  • Christine Berthold
  • Friedrich Johannes Auer
  • Sergej Potapov
  • Anselm Petschelt
چکیده

AIM To evaluate the influence of reinforcement material on in vitro dental splint rigidity. MATERIALS AND METHODS  A custom-made artificial model was used. The central incisors simulated 'injured' teeth with increased mobility, and the lateral incisors served as 'uninjured' teeth with physiologic mobility. The Periotest and Zwick methods were used to assess horizontal and vertical tooth mobility before and after splinting, and relative splint effect (SpErel) was calculated. Teeth 12-22 were splinted using two wire-composite splints (WCS), WCS1 (Dentaflex 0.45mm), and WCS2 (Strengtheners 0.8×1.8mm) as well as four quartz-fiber splints, QS1 (Quartz Splint UD 1.5mm), QS2 (Quartz Splint Rope 1.5mm), QS3 (Quartz Splint Woven 2.5mm), and QS4 (dry fibers 667 tex). The influence of the splint type was evaluated using anova, Tukey range, and the Dunnett-T3 test (α=0.05). To test the influence of initial tooth mobility, the t-test was applied (α=0.05). RESULTS  Reinforcement materials significantly influenced splint rigidity (P<0.05). The horizontal and vertical SpErel of WCS1 compared with WCS2 and QFSs1-4 was statistically significant (P<0.05). Significant differences were found when comparing the horizontal SpErel of WCS2 with WCS1 and QSs1-4 (P<0.05). SpErels of the 'injured' and 'uninjured' teeth showed significant differences (P<0.05). CONCLUSION  WCS1 is flexible compared with the more rigid WCS2 and QSs1-4. Initial tooth mobility influences SpErel. The flexible WCS1 can be recommended for splinting dislocation injuries whereas the semi-rigid/rigid WCS2 and QS1-4 can be used for horizontal root fractures and alveolar process fractures. The QS1-4 provide good esthetic outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage

Orthodontic and periodontal splints are prepared with round or flat metallic wires. As these devices cannot be used in patients with allergy to metals or with aesthetic demands, fiber-reinforced composite (FRC) retainers have been introduced. Stiffness of FRC materials could reduce physiologic tooth movement. In order to lower rigidity of conventional FRC retainers, a modified construction tech...

متن کامل

Spot-Bonding and Full-Bonding Techniques for Fiber Reinforced Composite (FRC) and Metallic Retainers

Fiber reinforced Composite (FRC) retainers have been introduced as an aesthetic alternative to conventional metallic splints, but present high rigidity. The purpose of the present investigation was to evaluate bending and fracture loads of FRC splints bonded with conventional full-coverage of the FRC with a composite compared with an experimental bonding technique with a partial (spot-) resin c...

متن کامل

بررسی مقایسه ای مقاومت به شکست سه نوع پست مختلف در بازسازی دندانهای اینسایزور شیری به شدت تخریب شده

Introduction & Objective: The management of mutilated primary incisors in early childhood caries is a clinical challenge. This study's purpose was to compare the resistance strength of 3 different types of posts in restoring broken primary incisors: (1) composite posts, (2) ortho-dontic wire posts and (3) quartz fiber posts. Materials & Methods: This semi experimental in vitro study was perfo...

متن کامل

Comparison of Custom-made Versus Prefabricated Thumb Splinting for Carpometacarpal Arthrosis: A Systematic Review and Meta-analysis

Background: The goal of this study was to compare the two types of orthoses, prefabricated soft splints versus shortthermoplastic custom-made splints, that are the most commonly used for the management of first carpometacarpal(CMC) osteoarthritis (OA).Methods: We conducted a meta-analysis and systematic review in the literature based on the Preferred ReportingItems for Systematic Reviews and Me...

متن کامل

مطالعه فعالیت الکتریکی عضلات ساق پا در مردان ورزشکار مبتلا به Shin Splints

هدف: ثبت فعالیت الکتریکی عضلات می تواند اطلاعاتی در خصوص میزان فعال شدن عضلات ساق در افراد مبتلا به شینShin Splints بدهد، بنابراین هدف از مطالعه حاضر ارزیابی فعالیت الکتریکی عضلات ساق پا در مردان ورزشکار مبتلا به Shin Splints بود. روش بررسی: تعداد 30 دانشجوی تربیت بدنی در این تحقیق شرکت کردند.فعالیت الکتریکی عضلات درشت نئی قدامی و دوقلو (داخلی و خارجی) به ترتیب در وضعیت Dorsiflexion و Plantar f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental traumatology : official publication of International Association for Dental Traumatology

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2012