Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users' needs?

نویسندگان

  • D J McLaughlin
  • R B Mooney
چکیده

AIM To assess the effectiveness and economy of routinely using commercially available in-plane bismuth shielding during CT scanning of the chest and brain. METHODS AND MATERIALS Forty patients were scanned with thermoluminescent dosemeters (TLDs) in situ to measure the radiation dose to the thyroid and eye during CT scanning of the brain and chest. Half of the patients had the "AttenuRad" shield in place during scanning. RESULTS Use of the shielding reduced the mean dose to the eye from 6.0 +/- 0.3 mGy to 4.9 mGy +/- 0.2 mGy and the thyroid dose from 16.4 mGy +/- 1.2 mGy to 7.1 mGy +/- 0.5 mGy. CONCLUSION Use of the thyroid shield is recommended for all CT scanning of the chest. The eye shield does not produce as marked a reduction in radiation dose to the lens of the eye, when an angled gantry is used, since the eyes are not in the primary beam. Use of the eyeshield is justifiable where irradiation of the orbit is unavoidable, although whether artifacts would be a problem if the shield was used in this way was not assessed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

Radioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield

Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim of this study was to develop a new radioprotective gonad shields to be use in pediatric pelvic radiography. Materials and Methods: The commercially available 0.06 mm lead equivalent bismuth garment has cropped squar...

متن کامل

حفاظت پرتویی بیماران در سی تی آنژیوگرافی قلب

Introduction: Cardiac CT (Computed Tomography) angiography applies as a pre-exam method for evaluating the patients with medical problems in their cardiac arteries. Due to the high delivered dose in this imaging method, dose reduction techniques and imaging strategies that serve the images quality with minimum patient dose are the subjects for investigation and research studies. This study will...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical radiology

دوره 59 5  شماره 

صفحات  -

تاریخ انتشار 2004