In vitro investigation of friction at the interface between bone and a surgical instrument.

نویسندگان

  • Jugal Parekh
  • Duncan E T Shepherd
  • David W L Hukins
  • Carl Hingley
  • Nicola Maffulli
چکیده

This study investigated the friction between surgical instruments and bone to aid improvements to instrument design. The bases of orthopaedic surgical instruments are usually made of metal, especially stainless steel. Silicone elastomer was chosen as an alternate biocompatible material, which would be compliant on the bone surface when used as the base of an instrument. The coefficient of static friction was calculated at the bone/material interface in the presence of a synthetic solution that had a comparable viscosity to that of blood, to assess the friction provided by each base material. Three types of silicone elastomers with different hardnesses (Shore A hardness 23, 50 and 77) and three distinct stainless steel surfaces (obtained by spark erosion, sand blasting and surface grinding) were used to assess the friction provided by the materials on slippery bone. The bone specimens were taken from the flattest region of the femoral shaft of a bovine femur; the outer surfaces of the specimens were kept intact. In general, the stainless steel surfaces exhibited higher values of coefficient of static friction, compared to the silicone elastomer samples. The stainless steel surface finished by spark erosion (surface roughness Ra  = 8.9 ± 1.6 µm) had the highest coefficient value of 0.74 ± 0.04. The coefficient values for the silicone elastomer sample with the highest hardness (Dow Corning Silastic Q7-4780, Shore A hardness 77) was not significantly different to values provided by the stainless steel surface finished by sand blasting (surface roughness Ra  = 2.2 ± 0.1 µm) or surface grinding (surface roughness Ra  = 0.1 ± 0.0 µm). Based on the results of this study, it is concluded that silicone could be a potentially useful material for the design of bases of orthopaedic instruments that interface with bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Numerical investigation on the pullout shear strength of soil-nail interface using finite element method

Soil nailing is a popular reinforcement method for stabilizing slopes, excavations, and retaining walls in many countries. The pullout capacity of the soil-nail interface is a critical parameter for the design and safety assessment of soil-nailed systems. In this paper, a three-dimensional (3D) finite element (FE) model is developed using the commercial program ABAQUS to simulate the pullout te...

متن کامل

Phase transition of the dry friction between crystalline surfaces induced by normal load

A major source of energy dissipation and surface wear is the kinetic friction at the interfaces of sliding bodies. Traditionally, on a macroscopic scale, this undesirable effect is reduced with lubricating the surfaces by introducing oil into their interface. An interesting phenomenon, called superlubricity, has been reported on a nanometer scale where dry (without lubricant oil) fruition and w...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Bimetal friction stir welding of aluminum to magnesium

FSW material flow and phase transformation were studied at the interface of dissimilar welding of Al 6013 to Mg. Defect free butt weld was obtained when aluminum and magnesium test plates were placed in the advancing side and retreating side respectively, and the tool was placed 1 mm off the weld centerline into the aluminum side. In order to understand how the materials flow during FSW, steel ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 227 6  شماره 

صفحات  -

تاریخ انتشار 2013