Evaluation of selectivity in multimodal anion exchange systems: a priori prediction of protein retention and examination of mobile phase modifier effects.

نویسندگان

  • Ying Hou
  • Steven M Cramer
چکیده

Although recent advances in multimodal chromatography have shown significant potential for selective protein purification, there is a need to establish a deeper understanding of the nature of selectivity in these systems. In this work, the adsorption behavior of a library of commercially available proteins with varying physicochemical properties was investigated. Linear gradient experiments were carried out with the multimodal anion exchanger and the results were compared to those obtained with a traditional anion exchange material. Proteins were more strongly retained on the multimodal resin and a different elution pattern was obtained as compared to anion exchange. Quantitative structure-property relationship models using a support vector regression technique were developed and the resulting models were shown to have good predictive abilities in both systems. Molecular descriptors selected during the generation of these models suggested that multiple interaction modes contributed to the stronger retention and different elution patterns observed in the multimodal system. Finally, mobile phase modifiers such as ethylene glycol, urea and arginine were shown to be able to impart unique selectivity trends in multimodal chromatography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL

Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...

متن کامل

Prediction of the effect of mobile-phase salt type on protein retention and selectivity in anion exchange systems.

This study examines the effect of different salt types on protein retention and selectivity in anion exchange systems. Particularly, linear retention data for various proteins were obtained on two structurally different anion exchange stationary-phase materials in the presence of three salts with different counterions. The data indicated that the effects are, for the most part, nonspecific, alt...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1218 43  شماره 

صفحات  -