Comparative analysis of immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay using virus-like particles or virus-infected mouse brain antigens to detect IgM antibody in sera from patients with evident flaviviral infections.

نویسندگان

  • Derek A Holmes
  • David E Purdy
  • Day-Yu Chao
  • Amanda J Noga
  • Gwong-Jen J Chang
چکیده

The use of immunoglobulin M (IgM) antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA) serves as a valuable tool for the diagnosis of acute flaviviral infections, since IgM antibody titers are detectable early, peak at about 2 weeks postinfection, and subsequently decline to lower levels over the next few months. Traditionally, virus-infected tissue culture or suckling mouse brain (SMB) has been the source of viral antigens used in the assay. In an effort to provide a reliable source of standardized viral antigens for serodiagnosis of the medically important flaviviruses, we have developed a eukaryotic plasmid vector to express the premembrane/membrane and envelope proteins which self-assemble into noninfectious virus-like particles (VLPs). In addition to the plasmids for Japanese encephalitis virus, West Nile virus (WNV), St. Louis encephalitis virus (SLEV), and dengue virus type 2 (DENV-2) reported earlier, we recently constructed the DENV-1, -3, and -4 VLP expression plasmids. Three blind-coded human serum panels were assembled from patients having recent DENV, SLEV, and WNV infections to assess the sensitivity and specificity of the MAC-ELISA using VLPs or SMB antigens. In addition, serum specimens from patients infected with either Powassan virus or La Crosse encephalitis virus were used to evaluate the cross-reactivity of seven mosquito-borne viral antigens. The results of the present studies showed higher sensitivity when using SLEV and WNV VLPs and higher specificity when using SLEV, WNV, and the mixture of DENV-1 to -4 VLPs in the MAC-ELISA than when using corresponding SMB antigens. Receiver operating characteristic (ROC) curve analysis, a plot of the sensitivity versus false positive rate (100 - specificity), was applied to discriminate the accuracy of tests comparing the use of VLPs and SMB antigen. The measurement of assay performance by the ROC analysis indicated that there were statistically significant differences in assay performance between DENV and WNV VLPs and the respective SMB antigens. Additionally, VLPs had a lower cutoff positive/negative ratio than corresponding SMB antigens when employed for the confirmation of current infections. The VLPs also performed better than SMB antigens in the MAC-ELISA, as indicated by a higher positive prediction value and positive likelihood ratio test. Cell lines continuously secreting these VLPs are therefore a significantly improved source of serodiagnostic antigens compared to the traditional sources of virus-infected tissue culture or suckling mouse brain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoglobulin M antibody test to detect genogroup II Norwalk-like virus infection.

Sera obtained from adult volunteers inoculated with genogroup II Norwalk-like viruses (NLVs), Hawaii virus, and Snow Mountain virus and from patients involved in outbreaks of gastroenteritis were tested for genogroup II NLV Mexico virus-specific immunoglobulin M (IgM) by use of a monoclonal antibody, recombinant Mexico virus antigen (rMXV)-based IgM capture enzyme-linked immunosorbent assay (EL...

متن کامل

Nonstructural protein 1-specific immunoglobulin M and G antibody capture enzyme-linked immunosorbent assays in diagnosis of flaviviral infections in humans.

IgM antibody- and IgG antibody-capture enzyme-linked immunosorbent assays (MAC/GAC-ELISAs) targeted at envelope protein (E) of dengue viruses (DENV), West Nile virus, and Japanese encephalitis virus (JEV) are widely used as serodiagnostic tests for presumptive confirmation of viral infection. Antibodies directed against the flavivirus nonstructural protein 1 (NS1) have been proposed as serologi...

متن کامل

Noninfectious recombinant antigen for detection of St. Louis encephalitis virus-specific antibodies in serum by enzyme-linked immunosorbent assay.

Proper surveillance of virus activity and a timely response to viral outbreaks depend upon the rapid diagnosis of viral infections. The immunoglobulin M (IgM) antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA) is a fast, sensitive test routinely used for the diagnosis of the medically important West Nile and St. Louis encephalitis flaviviruses. However, the suckling mouse brain-deri...

متن کامل

Evaluation of a West Nile virus immunoglobulin A capture enzyme-linked immunosorbent assay.

An in-house-developed enzyme-linked immunosorbent assay detected West Nile virus (WNV) immunoglobulin A (IgA) in 65 of 68 sera from WNV-infected patients; 40 of 63 WNV IgM-positive, IgG-negative serum or plasma specimens; 65 of 67 WNV IgM-positive, IgG-positive specimens; 0 of 70 WNV IgM-negative, IgG-negative specimens; and 0 of 64 archived blood donation sera. WNV IgA is thus highly prevalent...

متن کامل

Serotype-cross-reactive immunoglobulin M responses in dengue virus infections determined by enzyme-linked immunosorbent assay.

We developed immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assays (ELISAs) with four monovalent dengue virus antigens. We attempted to determine whether IgM responses in dengue virus infections are serotype specific or serotype cross-reactive. Serum samples from 14 confirmed dengue cases were examined. In these 14 cases, which consisted of 12 Japanese and 2 non-Japanese pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 2005