Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows

نویسندگان

  • Barbara Locher
  • André Piquerez
  • Manuel Habermacher
  • Martina Ragettli
  • Martin Röösli
  • Mark Brink
  • Christian Cajochen
  • Danielle Vienneau
  • Maria Foraster
  • Uwe Müller
  • Jean Marc Wunderli
چکیده

Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loudness and Annoyance Response to Simulated Outdoor and Indoor Sonic Booms

SUMMARY The sonic boom simulator of the Langley Research Center was used to quantify subjective loudness and annoyance response to simulated indoor and outdoor sonic boom signatures. The indoor signatures were derived from the outdoor signatures by application of house filters that approximated the noise reduction characteristics of a residential structure. Two indoor listening situations were ...

متن کامل

The effect of children’s gender on the outdoor design of kindergartens and preschools based on Islamic thought

Gender has a key role in Islamic thought and considers it as an aspect should be trained. Now a days in light of psychological and social studies, there are more information about gender differences. These differences influence education and training via “gender identity” and “sex-typing”. So it’s essential to consider gender differences in out door open spaces design. The goal of this study co...

متن کامل

بررسی استرس گرمایی در مشاغل کوچک شهرستان قم

Introduction: Heat stress in workplaces cause multiple problems such as thermal stresses, thermal discomfort and in more severe cases may lead to accidents and diseases related to excessive heat. The aim of this study was to evaluate heat stress adopting WBGT Index in some small enterprise in Qom city and also to examine the relationship between WBGT and physiological indices. . Material and M...

متن کامل

بررسی غلظت ذرات قابل استنشاق در کلاس های مدارس ابتدایی مرکز شهر ساری

Background and purpose: High concentrations of respirable particles in both the outdoor and indoor environments are associated with adverse health effects that could reduce the performance of students. This study was carried out to investigate the indoor concentrations of respirable particle and outdoor concentrations of PM2.5 at classrooms in primary schools in Sari, north of Iran. We also eva...

متن کامل

Indoor air quality monitoring in urban areas using Smart Sensing Technology

Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2018