Results with two ultramicro methods for plasma uric acid analysis with uricase are described: a crystal violet (gentian violet) method, modified from an automated procedure by Gochman and Schmitz [C/in. Chem. 17, 1154 (1971)] and adapted to manual analysis, and a polarographic oxygen-sensing system (Beckman Instruments,Inc.).The coefficientof variation (CV) for the crystal violet method varied between 2.1 and 5.7% for an 11-month period. Within-run precision (CV) of the polarographic method was 3.3%; day-to-day CV varied between 3.4 and 9.4%. Percentage recovery for the crystal violet method ranged between 97 and 106%, and for the polarographiC method between 92 and 100%. Results of the two methods correlate well, but 5-15% lower values are obtained by the crystal violet method than by the polarographic method. Bilirubin, hemolysis,or usual plasma concentrationsof ascorbic acid do not interfere significantly witheithermethod. Advantages and disadvantagesof both methods are discussed. The polarographic method requires more uricase, but is the better of the two methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immobilized uricase for automated assay of uric acid in serum

The wide use of bound enzyme coils with hexokinase and glucose-6-phosphate dehydrogenase in automated analysis for serum-glucose assay [1, 2-] demonstrates the potential of open tubular heterogeneous enzyme reactors [3] in clinical analysis. Such reactors have also been prepared with other enzymes I-4, 5] and in this paper the authors describe a continuous-flow method for uric acid assay with i...

متن کامل

Hyperxanthinemia interferes with serum uric acid determinations by the uricase method.

Serum xanthine concentrations as high as 148 mg/L were noted after treatment of a patient with Burkitt's lymphoma who was receiving allopurinol. These markedly above-normal values for xanthine led to spuriously low values for serum uric acid as measured by the uricase method. Rapid tumor lysis in patients who are receiving allopurinol may lead to marked hyperxanthinemia, which in turn may obscu...

متن کامل

Effect of minerals on activity of microbial uricase to reduce ammonia volatilization in poultry manure.

Inhibition of microbial uricase in poultry manure is critical to reduce NH3 volatilization, because hydrolysis of uric acid by microbial uricase is the first step in the production of NH3 gas in poultry manure. Three experiments were conducted to evaluate the effects of minerals on uricase activity and NH3 volatilization from poultry manure. In Experiment 1, an in vitro enzyme assay was used to...

متن کامل

Comparison of carbonate and uricase-carbonate methods for the determination of uric acid in serum.

A colorimetric carbonate procedure for the determination of uric acid has been modified to include incubation of serum with uricase to destroy uric acid. Residual nonurate chromogens are subtracted from total chromogens to obtain the concentration of “true” uric acid. Result obtained by the carbonate and the uricase-carbonate methods were in good agreement. The mean concentration of nonurate ch...

متن کامل

The end-products and intermediates of uric acid oxidation by uricase.

Since the early work on uricase carried out by Schittenhelm (l), Wiechowski (a), and Battelli and Stern (3), and t,he elucidation of the structure of uric acid by the work of Behrend and Roosen (4), Fischer (5), and Biltz (6), the chemical nature of the intermediates and end-products of uricase action has been uncertain. The first indications of the structure of a possible intermediate were off...

متن کامل

Comparison of four methods for measuring uric acid: copper-chelate, phosphotungstate, manual uricase, and automated kinetic uricase.

Glutathione,ascorbicacidand many commonly used antibiotics falsely elevate uric acid concentrations when measured with the Du Pont “aca,” in which the copper-chelate method is used. L-Dopa interferes with both the copper-chelate method and the Technicon “SMA 12/60” phosphotungstate method. A new kinetic uricase method has been developed for use on the Du Pont aca. This kinetic uricase method ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004