CLEO III Silicon Vertex Detector and Assembly Database

نویسنده

  • Raphael Thomas
چکیده

The vertex detector currently in operation at the Cornell Electron-positron Storage Ring (CESR) will be upgraded with a new four-layer double-sided silicon vertex detector. I have designed a database to keep track of massive amounts of information on the status and quality of each of the 511 detector channels and the corresponding readout electronics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Object Database for Constants : The common CLEO Online and Offline solution

After the successful conclusion of the CLEO III phase, the CLEO experiment at the Cornell electron positron storage ring CESR is preparing for its transition to CLEO-c. This new program contains a wide array of Physics studies at e + e − collisions at center of mass energies between 3 GeV and 5 GeV that will provide new insights into QCD. Because the existing Silicon Vertex Detector needed to b...

متن کامل

The CLEO III Upgrade

The CLEO detector at the Cornell Electron Storage Ring (CESR) is completing a major upgrade that significantly extends its physics reach in the study of heavy quarks and leptons. The major elements of this detector upgrade are the installation of a “fast” ring imaging Cherenkov detector, a new central drift chamber and a new barrel-style silicon strip vertex detector. Trigger and data acquisiti...

متن کامل

Beam Backgrounds at CLEO : Design andPerformance of the

2 Abstract In November 1995, the Cornell Electron Storage Ring (CESR) began Phase II operations. The CESR/CLEO Phase II upgrade involved the installation of a silicon vertex detector for the CLEO experiment and an interaction region optimized for a small-radius beampipe and bunch-train collisions at total beam currents of 600 mA. The design of the CESR Phase II Interaction Region is described a...

متن کامل

D Mixing and Cabibbo Suppressed Decays

The CLEO collaboration reported observation of the ‘wrong sign’ decay D → Kπ in 1993. Upgrades have been made to the CLEO detector , including installation of a silicon vertex detector, which provide substantial improvements in sensitivity to D→Kπ. The vertex detector enables the reconstruction of the proper lifetime of the D, and so provides sensitivity to D−D mixing. We will give preliminary ...

متن کامل

The Power Supply System of the CLEO III Silicon Detector

The CLEO III detector has recently commenced data taking at the Cornell electron Storage Ring (CESR). One important component of this detector is a 4 layer doublesided silicon tracker with 93% solid angle coverage. This detector ranges in size and number of readout channels between the LEP and LHC silicon detectors. In order to reach the detector performance goals of signal-to-noise ratios grea...