Intraocular Pressure Changes: An Important Determinant of the Biocompatibility of Intravitreous Implants
نویسندگان
چکیده
BACKGROUND In recent years, research efforts exploring the possibility of using biomaterial nanoparticles for intravitreous drug delivery has increased significantly. However, little is known about the effect of material properties on intravitreous tissue responses. PRINCIPAL FINDINGS To find the answer, nanoparticles made of hyaluronic acid (HA), poly (l-lactic acid) (PLLA), polystyrene (PS), and Poly N-isopropyl acrylamide (PNIPAM) were tested using intravitreous rabbit implantation model. Shortly after implantation, we found that most of the implants accumulated in the trabecular meshwork area followed by clearance from the vitreous. Interestingly, substantial reduction of intraocular pressure (IOP) was observed in eyes implanted with particles made of PS, PNIPAM and PLLA, but not HA nanoparticles and buffered salt solution control. On the other hand, based on histology, we found that the particle implantation had no influence on cornea, iris and even retina. Surprisingly, substantial CD11b+ inflammatory cells were found to accumulate in the trabecular meshwork area in some animals. In addition, there was a good relationship between recruited CD11b+ cells and IOP reduction. CONCLUSIONS Overall, the results reveal the potential influence of nanoparticle material properties on IOP reduction and inflammatory responses in trabecular meshwork. Such interactions may be critical for the development of future ocular nanodevices with improved safety and perhaps efficacy.
منابع مشابه
The effect of low dose of ketamine on intraocular pressure in patients undergoing cataract surgery
Background: Cataract surgery is one of the most common surgeries in the world, especially in elderly patients, and often performed topically with sedative agents. Ketamine is one of the most commonly used agents and the effect of different doses on intraocular pressure is in dispute. The present study investigates the effect of a low dose of ketamine on intraocular pressure in patients undergoi...
متن کاملIntravitreous bevacizumab injection: an experimental study in New Zealand white rabbits.
OBJECTIVES To determine the effects of intraocular pressure (IOP) and needle diameter on the amount of reflux after intravitreous bevacizumab injection. METHODS Prospective randomized interventional study. Twelve New Zealand white rabbits weighing approximately 2.5 to 3.5 kg each were randomized 1:1 to group 1 or group 2. Bevacizumab stained with trypan blue was used for intravitreous injecti...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملWhat is the Real Cause of Glaucoma?
Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...
متن کاملThe Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting
Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2011