Axial shrinkage-stress depends upon both C-factor and composite mass.
نویسندگان
چکیده
OBJECTIVES To measure and then mathematically model polymerization stress-dependence upon systematic variations of C-factor (bonded/unbonded area ratio) for the Bioman instrument [1], recording stress by free cantilever-beam deflection; compliance 1.5 microm/MPa. METHODS A light-cured resin-composite (RZD103; Ivoclar) with 57% (v/v) 450 nm filler was studied. Facing surfaces: glass slab and steel rod-end, constituting the Bioman test chamber, being perpendicular to the measured axial stress-direction, were varied: (a) with rod-diameters (phi), from 1 to 10mm in 1mm increments (with 0.8mm gap height); and then (b) with gap heights (h) in 16 steps from 0.05 to 1.50mm (with phi=10mm). For each h and phi combination, giving C-factors ranging from 0.6 to 100, shrinkage-stress was recorded for 1h from start of 40s irradiation at 600 mW cm(-2) for photo-polymerization at 23 degrees C (n=3). Shrinkage-stress (S(sigma)) was plotted directly as functions of h, phi, and C and also per unit composite mass, (S(sigma)g(-1)). ANOVA and Tukey's statistics were applied. RESULTS Series A-diameter variation; with C-factor increasing from 0.6 to 6, gave an exact exponential decrease in S(sigma) from 45 to 8 MPa. Series B-height variation; with C-factor increasing from 3 to 100, gave increasing S(sigma) from 1 to 8 MPa. Since composite mass played an equally dominant role, plots of stress-variations per unit composite mass, (S(sigma)g(-1)) separated these effects, confirming progressive off-axial stress-relief with increasing h. SIGNIFICANCE (i) Values of h=0.8 and phi=10mm, recommended [1] for Bioman use, were confirmed as appropriate. Every lab instrument for measuring S(sigma) necessarily embodies specific C-factors and compliance values in the instrument design. (ii) Configuration (C) factor is recognized as an important parameter affecting manifestation of shrinkage-stress within restorative cavities and luting gaps. However, the restorative mass must equally be considered when translating shrinkage-science into specific clinical recommendations.
منابع مشابه
Effect of layering methods, composite type, and flowable liner on the polymerization shrinkage stress of light cured composites.
OBJECTIVES The aim of this study was to investigate the effect of layering methods, flowable composite liner and use of low shrinkage silorane-based composite on the polymerization shrinkage stress of light cured composites. METHODS Aluminum blocks were used to prepare MOD cavities and divided into four groups. A universal hybrid methacrylate-based composite (Z250), a flowable composite (Z350...
متن کاملEffect of Light-curing Units and Activation Mode on Polymerization Shrinkage and Shrinkage Stress of Composite Resins
The aim of this study was to evaluate the polymerization shrinkage and shrinkage stress of composites polymerized with a LED and a quartz tungsten halogen (QTH) light sources. The LED was used in a conventional mode (CM) and the QTH was used in both conventional and pulse-delay modes (PD). The composite resins used were Z100, A110, SureFil and Bisfil 2B (chemical-cured). Composite deformation u...
متن کاملPre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion.
OBJECTIVES To investigate the influence of pre-heating of high-viscosity bulk-fill composite materials on their degree of conversion and shrinkage force formation. METHODS Four bulk-fill composite materials (Tetric EvoCeram Bulk Fill-TECBF, x-tra fil-XF, QuixFil-QF, SonicFill-SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram-TEC) were used. The test materials were either k...
متن کاملEffect of modulated photo-activation on polymerization shrinkage behavior of dental restorative resin composites.
This study investigated the influence of modulated photo-activation on axial polymerization shrinkage, shrinkage force, and hardening of light- and dual-curing resin-based composites. Three light-curing resin composites (SDR bulk-fill, Esthet X flow, and Esthet X HD) and one dual-curing material (Rebilda DC) were subjected to different irradiation protocols with identical energy density (27 J c...
متن کاملPolymerization shrinkage stress of composites photoactivated by different light sources.
The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Dental materials : official publication of the Academy of Dental Materials
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2008