From clinical sample to complete genome: Comparing methods for the extraction of HIV-1 RNA for high-throughput deep sequencing.

نویسندگان

  • Marion Cornelissen
  • Astrid Gall
  • Monique Vink
  • Fokla Zorgdrager
  • Špela Binter
  • Stephanie Edwards
  • Suzanne Jurriaans
  • Margreet Bakker
  • Swee Hoe Ong
  • Luuk Gras
  • Ard van Sighem
  • Daniela Bezemer
  • Frank de Wolf
  • Peter Reiss
  • Paul Kellam
  • Ben Berkhout
  • Christophe Fraser
  • Antoinette C van der Kuyl
چکیده

The BEEHIVE (Bridging the Evolution and Epidemiology of HIV in Europe) project aims to analyse nearly-complete viral genomes from >3000 HIV-1 infected Europeans using high-throughput deep sequencing techniques to investigate the virus genetic contribution to virulence. Following the development of a computational pipeline, including a new de novo assembler for RNA virus genomes, to generate larger contiguous sequences (contigs) from the abundance of short sequence reads that characterise the data, another area that determines genome sequencing success is the quality and quantity of the input RNA. A pilot experiment with 125 patient plasma samples was performed to investigate the optimal method for isolation of HIV-1 viral RNA for long amplicon genome sequencing. Manual isolation with the QIAamp Viral RNA Mini Kit (Qiagen) was superior over robotically extracted RNA using either the QIAcube robotic system, the mSample Preparation Systems RNA kit with automated extraction by the m2000sp system (Abbott Molecular), or the MagNA Pure 96 System in combination with the MagNA Pure 96 Instrument (Roche Diagnostics). We scored amplification of a set of four HIV-1 amplicons of ∼1.9, 3.6, 3.0 and 3.5kb, and subsequent recovery of near-complete viral genomes. Subsequently, 616 BEEHIVE patient samples were analysed to determine factors that influence successful amplification of the genome in four overlapping amplicons using the QIAamp Viral RNA Kit for viral RNA isolation. Both low plasma viral load and high sample age (stored before 1999) negatively influenced the amplification of viral amplicons >3kb. A plasma viral load of >100,000 copies/ml resulted in successful amplification of all four amplicons for 86% of the samples, this value dropped to only 46% for samples with viral loads of <20,000 copies/ml.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strategies and Clinical Applications of Next Generation Sequencing

Abstract DNA sequencing is one of the great valuable techniques in molecular biology, which can be used to detect the sequence of nucleotides in a DNA fragment. The high-throughput se­quencing known as Next Generation Sequencing (NGS) revolutionized genomic research and molecular biology; therefore, the whole human genome can be sequenced with a low cost in several days. NGS technology is simi...

متن کامل

Strategies and Clinical Applications of Next Generation Sequencing

Abstract DNA sequencing is one of the great valuable techniques in molecular biology, which can be used to detect the sequence of nucleotides in a DNA fragment. The high-throughput se­quencing known as Next Generation Sequencing (NGS) revolutionized genomic research and molecular biology; therefore, the whole human genome can be sequenced with a low cost in several days. NGS technology is simi...

متن کامل

Optimization of RNA Extraction from Rat Pancreatic Tissue

Background: Optimized RNA extraction from tissues and cell lines consists of four main stages regardless of the method of extraction: 1) homogenizing, 2) effective denaturation of proteins from RNA, 3) inactivation of ribonuclease, and 4) removal of any DNA, protein, and carbohydrate contamination. Isolation of undamaged intact RNA is challenging when the related tissue contains high levels of ...

متن کامل

مروری برتکنیک های توالی یابی D‏NA (نسل اول، نسل دوم و نسل سوم)

Introduction: The DNA sequencing is the most important technique in molecular biology by which the order of the nucleotides can be identified in a piece of DNA. There are several different methods for sequencing the DNA. Now, the DNA sequencing has great importance in the medical diagnostics and other medical fields. Some methods have been invented to speed up and increase the efficiency of the...

متن کامل

The challenge of getting a high quality of RNA from oocyte for gene expression study

The extraction of intact RNA from oocyte is quite challenging and time-consuming. A standard protocol using commercial RNA extraction kit, yields a low quantity of RNA in oocytes. In the past, several attempts in getting RNA for gene expression study ended up with a few different modified methods. Extraction of high-quality RNA from oocyte is important before further downstream analyses such as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Virus research

دوره 239  شماره 

صفحات  -

تاریخ انتشار 2017