Reliability of the Hitachi sodium and potassium electrodes assessed.

نویسندگان

  • P Winkel
  • M Wilken
  • J Christiansen
  • B Buch
چکیده

We compared the Hitachi 705 E sodium/potassium electrode system with the Radiometer flame photometer for measuring concentrations of sodium and potassium ions in serum and plasma. Our data show that the Hitachi results are slightly but significantly (less than 0.001) lower than the flame photometer results: Na+ 1.33 mmol/L for serum and 2.24 mmol/L for plasma; K+ 0.062 mmol/L for serum and 0.082 mmol/L for plasma. The magnitude of the bias varied considerably from day to day, ranging from -0.10 to 2.33 mmol/L for Na+ in serum and from 0.00 to 0.11 mmol/L for serum K+; for plasma specimens the corresponding ranges were -0.03 to 5.97 mmol/L and 0.00 to 0.17 mmol/L. These variations probably reflected difficulties in reproducing the calibration from day to day, because the daily means for a serum pool varied in parallel. We occasionally encountered serious problems with reproducibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.

We evaluated the effect of hemolysis, icteric discoloration, lipemia, paraproteinemia, and uremia on enzymatic methods for determining sodium, potassium, and chloride, according to the National Committee for Clinical Laboratory Standards EP7-P proposals for testing interference from endogenous substances. The sodium, potassium, and chloride assays (reagent kits supplied by Boehringer Mannheim) ...

متن کامل

ارزیابی کیفیت هوای ورودی به توربین های گازی دریک نیروگاه

Introduction: Pollutants in gas turbine air intake can cause erosion ،corrosion، fouling as well as reduction of power and efficiency of turbine and noticeable economic losses. In order to select the appropriate filtration system, air monitoring of turbine inlet and its filtration is essential. Therefore, this study was performed to assess the quality of gas turbines inlets in a gas power plant...

متن کامل

Effects of hyperlipidemia on plasma sodium, potassium, and chloride measurements by an indirect ion-selective electrode measuring system.

To the Editor: We used indirect ion-selective electrode (ISE) methods (Roche/Hitachi Modular) to investigate the effect of hyperlipidemia (cholesterol plus triglycerides) on measurements of sodium, potassium, and chloride and the ability of published formulas to correct for the decrease in measured Na , K , and Cl . As recommended by Kroll (1 ), we did not use enriched samples but instead used ...

متن کامل

Inadequate measurement of urinary chloride.

Urinary electrolytes are invaluable in the differential diagnosis and treatment of certain acid-base diseases. We have evaluated the accuracy and precision of three different automated chemistry analyzers and a chloridometer (Corning 925 Chloridometer, Hitachi 717 and 917 and Vitros 950) for chloride, sodium and potassium using standard solutions. Data indicate that the ISE modules on the Hitac...

متن کامل

Axon clinical chemistry analyzer evaluated according to ECCLS protocol.

We assessed the analytical performance of the Axon system (Bayer Diagnostici), according to the European Committee for Clinical Laboratory Standards guidelines, for assay of 12 analytes: cholesterol, creatinine, glucose, total protein, urea, uric acid, alkaline phosphatase, alpha-amylase, aspartate aminotransferase, creatine kinase, sodium, and potassium. The field evaluation lasted approximate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 1985