R2* Measurement Using Absolute SNR-Weighted Least Square Regression

نویسندگان

  • X. Yin
  • S. Shah
  • A. C. Larson
چکیده

INTRODUCTION Accurate R2* measurements are critical for many quantitative imaging applications. R2* is estimated via mono-exponential fitting of signal decay within a series of gradient echo (GRE) images sampled at increasing TE. Root-sum-of-square (RSS) remains the most common approach to combine surface coil array images at each TE prior to the data fitting procedure. Rapid signal decay can result in poor SNR at later TEs. RSS approaches rectify and bias noise resulting in systematic fitting errors [1]. We previously studied the efficacy of combining truncation model with array coil combination methods to improve accuracy of R2* measurements in low SNR settings. Although truncation was found to be an effective method to reduce measurement error for RSS reconstructed data, the optimal truncation threshold was determined through brute-forced search (computationally intensive) with a priori knowledge of the anticipated R2* value [2]. The objective of this work was to investigate a less computationally exhaustive approach for R2* measurements with RSS reconstructed data (and no prior knowledge of anticipated R2*). We compared the accuracy of R2* measurements performed using SNR weighted least square (WLS) regression to R2* measurements using SNR-based truncation method in phantom, animal, and human studies. METHOD SNR measurement: For all TEs, we reconstructed RSS combined images in SNR units via pre-scan noise, data pre-whitening, and bias correction [3]. This approach allows absolute SNR measurement since voxel-wise noise characteristics are taken into account during SNR calculations. Comparison Studies: R2* maps were calculated via voxel-wise ordinary least-square (Method A: OLSALL) fitting and weighted least-square (Method B: WLSALL) fitting of the mono-exponential signal decay for all data echoes. By using its absolute SNR measurement as the weighting term at each TE, WLSALL weighted strongly high SNR TEs and weakly low SNR TEs. Similarly, R2* maps were also calculated via ordinary least-square fitting for truncated data (Method C: OLSTRUNC), where TEs with absolute SNR below a given threshold were excluded from R2* map calculations. Truncation thresholds were incremented from SNR=0 to SNR=20 (steps of 0.1 SNR units) for all studies. A minimum of two TEs were kept for all R2* estimations. Data Acquisition: R2* phantoms were constructed by filling cylindrical 2L polystyrene bottles with water doped with 1.6 mmol/L (Phantom I) or 0.8mmol/L (Phantom II) MnCl2.H2O. Ex vivo studies were performed on a recently euthanized rabbit. Abdominal axial scans were performed on 6 healthy volunteers according to our IRBapproved protocol. Phantom and ex-vivo studies were conducted using a 3T clinical scanner (Siemens Magnetom Trio) with 8-channel head coil. Volunteer studies were conducted using a 1.5T clinical scanner (Siemens Avanto) and a 32-channel surface coil array. A MGRE sequence was used with parameters: TR (phantom/ex vivo/abdomen)=5000/1000/100ms, TE=2-65ms, BW=640 Hz/pixel, 5mm slices and 24 echoes. For phantom and ex vivo studies, we achieved a range of SNR levels by using flip-angles (FA) = 1, 2, 5, and 10; reference standard R2* measurements were performed using 32 averaged datasets acquired using the body transmit/receive coil. For volunteer studies, FA=20 was used and we achieved different SNR levels by evaluating peripheral and central (high and low SNR) regions of within the liver. Data Analysis: For phantom and ex vivo studies, we computed voxel-wise absolute error (VAE) as the difference between reference standard R2* map and comparison R2* maps. RESULTS Phantom: R2* values were found to be 155 s for Phantom I and 80 s for Phantom II. At FA =1, 2, 5 and 10, OLSALL, WLSALL, and optimal OLSTRUNC (lowest error for truncation thresholds) are displayed in Fig.1 for both phantoms. VAE was reduced with increasing SNR (increased FA) and decreasing R2* value (Phantom I vs. II). Both WLS and truncation improved R2* measurement. While R2* estimations using optimal OLSTRUNC were more accurate than WLSALL, optimal OLSTRUNC required 40-80 iterations of truncation and was based on prior knowledge of anticipated R2* value. WLSALL improved R2* measurement accuracy without any prior knowledge of anticipated R2* and only required 1 iteration for computation. Ex vivo: R2* values were found to be 160 s for liver parenchyma and 50 s for gallbladder. Mean VAE for OLSALL, WLSALL, and optimal OLSTRUNC are displayed for both tissues at FA =1, 2, 5 and 10 in Fig.2. Error decreased with increasing SNR/FA and decreasing R2* value (liver vs. gallbladder). WLS algorithm improved R2* measurement but didn’t outperform optimal OLSTRUNC. However, optimal OLS TRUNC required iterations of truncation with prior knowledge of anticipated R2* values. Normal Volunteer Studies: For a representative volunteer study, we selected ROIs in the peripheral and central region of the liver parenchyma (high vs. low SNR), shown in Fig. 3A. R2* measurements for OLSTRUNC at SNR threshold from 0 to 20 for are shown in Fig.3B. R2*s from peripheral ROI are relatively constant at all thresholds, while R2*s for central ROI increased as SNR thresholds increased. For all six normal volunteers, optimal OLSTRUNC R2* values were selected at the threshold where R2* values for both ROIs are closest (as labeled in Fig.3b). R2* values from all three methods (across all volunteers) are shown in boxplot Fig. 3C. In peripheral ROI, R2* measurements from all three methods are similar and can be viewed as the “relative reference standard”. In central ROI, R2* values for both WLSALL and optimal OLSTRUNC were close to the relative reference standard but no prior knowledge of anticipate R2* value was needed required for WLSALL method. CONCLUSION R2* measurement accuracy improved with increased SNR and slower signal decay rates. SNR weighted least square algorithm and SNR-based truncation are both effective methods in reducing R2* measurement error. In clinical settings, where prior knowledge of anticipated R2* values and the optimal SNR truncation threshold are generally unknown, the SNR weighted least square algorithm is a fast and reliable approach for accurate R2* measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved R2* measurement accuracy with absolute SNR truncation and optimal coil combination.

Accurate R2* measurements are critical for many abdominal imaging applications. Conventionally, R2* maps are derived via the monoexponential fitting of signal decay within a series of gradient-echo (GRE) images reconstructed from multichannel datasets combined using a root sum-of-squares (RSS) approach. However, the noise bias at low-SNR TEs from RSS-reconstructed data often causes the underest...

متن کامل

Simultaneous Measurement of Antenna Gain and Complex Permittivity of Liquid in Near-Field Region Using Weighted Regression

As a technique for calibrating electric-field probes used in standardized SAR (Specific Absorption Rate) assessment, we have studied the technique using the Friis transmission formula in the tissue-equivalent liquid. It is difficult to measure power transmission between two reference antennas in the far-field region due to large attenuation in the liquid. This means that the conventional Friis ...

متن کامل

Comparative Analysis of Hybrid Models for Prediction of BP Reactivity to Crossed Legs

Crossing the legs at the knees, during BP measurement, is one of the several physiological stimuli that considerably influence the accuracy of BP measurements. Therefore, it is paramount to develop an appropriate prediction model for interpreting influence of crossed legs on BP. This research work described the use of principal component analysis- (PCA-) fused forward stepwise regression (FSWR)...

متن کامل

Predicting active-layer soil thickness using topographic variables at a small watershed scale

Knowledge about the spatial distribution of active-layer (AL) soil thickness is indispensable for ecological modeling, precision agriculture, and land resource management. However, it is difficult to obtain the details on AL soil thickness by using conventional soil survey method. In this research, the objective is to investigate the possibility and accuracy of mapping the spatial distribution ...

متن کامل

A comparison of least squares regression and geographically weighted regression modeling of West Nile virus risk based on environmental parameters

BACKGROUND The primary aim of the study reported here was to determine the effectiveness of utilizing local spatial variations in environmental data to uncover the statistical relationships between West Nile Virus (WNV) risk and environmental factors. Because least squares regression methods do not account for spatial autocorrelation and non-stationarity of the type of spatial data analyzed for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009