Continuous separation of biomolecules by the laterally asymmetric diffusion array with out-of-plane sample injection.
نویسندگان
چکیده
The laterally asymmetric diffusion array, a biomolecule sorting device, was used to continuously separate a mixture of T2 and T7 coliphage DNA molecules into its constituents. A two-dimensional array of obstacles (in the presence of an average flow v) can be used to rectify the Brownian motion of particles (in this case DNA molecules) so that they diffuse preferentially in one direction, and perpendicular to the direction of the applied field (in this case an electric field). This type of device had not yet been used for actual fractionation of biomolecules, due to difficulties in injection of the sample. Here we show that with a new injection strategy a well-defined, narrow and continuous stream of molecules can be injected into the separation channel, thus enabling this separation technique to be used in a working device. We expect this type of device could now be employed for separation of a variety of different biomolecules, ranging from long dsDNA to small proteins.
منابع مشابه
Optimization of Array Factor in Linear Arrays Using Modified Genetic Algorithm
The array factor (sidelobe level, SLL) of a linear array is optimized using modified continuous genetic algorithms in this work. The amplitudes and phases of the currents as well as the separation of the antennas are all taken as variables to be controlled. The results of the design using modified GA versions are compared with other methods. Two design problems were studied using several contin...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملChiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis
Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...
متن کاملAn investigation of using hump in the Cherenkov photon lateral distribution for Gamma-Hadron separation
Simulation of gamma and hadron showers in the energy range 100GeV- 25TeV has been carried out. For a big ideal Cherenkov light array, characteristics of lateral distribution of Cherenkov photon density have been studied. Results from this ideal detector are compared with those simulated for a real TUNKA- like array to investigate experimental potential of using existence of a hump in lateral di...
متن کاملNanofluidic devices for rapid continuous-flow bioseparation.
Compared with conventional gel-based techniques, such as gel electrophoresis, which are routinely used for bioseparation in biology and biomedical laboratories, nanofluidic devices with regular engineered sieving structures offer the potential for faster separation, better resolution, higher throughput, and more convenient sample recovery. Here, we detail the fabrication process of a two-dimens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Electrophoresis
دوره 23 20 شماره
صفحات -
تاریخ انتشار 2002