Correction of CSF motion artifact on MR images of the brain and spine by pulse sequence modification: clinical evaluation.

نویسندگان

  • N M Szeverenyi
  • S A Kieffer
  • E D Cacayorin
چکیده

A modification of the standard spin-echo pulse sequence designed to suppress motion artifacts was clinically evaluated on T2-weighted MR images of the cervicocranial region. A retrospective study involving 40 patients, half of whom were examined with a standard T2-weighted multislice spin-echo sequence and half of whom were examined with a gradient waveform modification of the same sequence, uniformly demonstrated restoration of CSF signal intensity on images obtained with the gradient modified sequence. The cervical subarachnoid spaces, cisterna magna, medullary cistern, pontine cistern, fourth ventricle, and aqueduct were more consistently and brightly represented. However, the phase-encoding artifacts arising from CSF motion were not significantly reduced by using the gradient waveform modified pulse sequence. Digital subtraction of an image obtained with the standard sequence from an image of the same slice with the gradient modified sequence provides a direct image representation of CSF flow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 1988