Coronary calcium score scan-based attenuation correction in cardiovascular PET imaging.
نویسندگان
چکیده
OBJECTIVE Cardiac positron emission tomography (PET)/CT imaging is a noninvasive procedure allowing the assessment of coronary artery disease (CAD). CT-based attenuation correction of PET data is essential for accurate quantitative analysis in PET/CT imaging. Coronary artery calcium scoring CT (CaScCT) is used as a noninvasive tool for the diagnosis of atherosclerosis in patients with medium risk for CAD. In addition to the CaScCT examination, current cardiac rest/stress NH3 or ¹⁸F-fluorodeoxyglucose viability PET/CT protocols incorporate a correlated low-dose CT scan for attenuation correction purposes (ACCT). As a result, the patient receives a non-negligible radiation dose. The aim of this study is to evaluate the possibility of using CaScCT images for AC of myocardial rest/stress/viability PET data with the aim of reducing patient dose. METHODS Since in cardiac PET/CT protocols, the CaScCT examination is usually reconstructed using a small field-of-view, the CaScCT data were reconstructed again with extended field-of-view (ExCaScCT) and used for AC of the corresponding PET data. The feasibility study was performed using 10 patients including four NH3 perfusion and six ¹⁸F-fluorodeoxyglucose viability examinations acquired on the Biograph TP 64 PET/CT scanner. The assessment of PET images corrected using both ACCT and ExCaScCT images was carried out through qualitative assessment performed by an expert nuclear medicine specialist in addition to the regression analysis and the Bland-Altman plots, and 20-segment myocardial bull's eye view analysis. RESULTS Despite the good agreement between PET images corrected using ACCT and ExCaScCT images as expressed by the correlation coefficient and slope of the regression line in viability (0.949 ± 0.041 and 0.994 ± 0.124) and stress perfusion examinations (0.944 ± 0.008 and 0.968 ± 0.055), the rest perfusion examinations had weak correlation (0.454 ± 0.203 and 0.757 ± 0.193). This is attributed to the fact that the CaScCT scan is performed immediately after the stress/viability ACCT in our protocol that leads to a small misalignment between the CaScCT and stress/viability ACCT images, whereas there is a large misalignment between the CaScCT and rest ACCT images. The bull's eye view analysis showed that the difference between the uptake values was larger in the inferior wall because of diaphragm motion. CONCLUSION Our preliminary results seem to suggest that the calcium score study could be used for attenuation correction of cardiac PET images, thus allowing the elimination of ACCT in viability and stress perfusion studies and as such reduce patient dose.
منابع مشابه
Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?
Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...
متن کاملMeasuring coronary artery calcification using positron emission tomography-computed tomography attenuation correction images.
AIMS Cardiac computed tomography (CT) measured coronary artery calcium (CAC-CT) is a well-validated and accurate tool for estimating atherosclerotic burden and prognosis. Computed tomography attenuation correction (ACCT) obtained during cardiac positron emission tomography (PET) has been used to visually estimate CAC; however, quantification using a non-gated ACCT images has not been described....
متن کاملEstimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom
One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nuclear medicine communications
دوره 31 9 شماره
صفحات -
تاریخ انتشار 2010