Cost-effectiveness of the Boston keratoprosthesis.

نویسندگان

  • Jared D Ament
  • Tomasz P Stryjewski
  • Joseph B Ciolino
  • Amit Todani
  • James Chodosh
  • Claes H Dohlman
چکیده

PURPOSE To conduct a cost-utility analysis and determine the cost-effectiveness of the Boston Keratoprosthesis (Boston Kpro). DESIGN Retrospective cohort study. METHODS setting: The Massachusetts Eye and Ear Infirmary corneal service. patients: Inclusion required a minimum 2-year follow-up. Patients with autoimmune diseases and chemical burns were excluded. Eighty-two patients were included with various indications for surgery. intervention: The keratoprosthesis is a collar button-shaped polymethylmethacrylate (PMMA) device consisting of 2 curved plates sandwiched around a corneal donor (allo)graft. The device is assembled intraoperatively and sutured to a patient's eye after removing the diseased cornea. MAIN OUTCOME MEASURES Average cost-effectiveness of the keratoprosthesis was determined by cost-utility analysis, using expected-value calculations and time-tradeoff utilities. The comparative effectiveness, or gain in quality-adjusted life years (QALYs), was also sought. Cost-effectiveness was compared to recently published data on penetrating keratoplasty (PK). RESULTS A total discounted incremental QALY gain for the Boston Kpro of 0.763 correlated with a conferred QALY gain of 20.3% for the average patient. The average cost-effectiveness of the keratoprosthesis was $16 140 per QALY. CONCLUSIONS Comparable to corneal transplantation, with a cost-effectiveness between $12 000 and $16 000 per QALY, the keratoprosthesis can be considered highly cost-effective.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Expanding indications for the Boston keratoprosthesis.

PURPOSE OF REVIEW To review emerging indications for the Boston keratoprosthesis (KPro) and to discuss current research underway to improve clinical outcomes. RECENT FINDINGS In addition to multiple failed corneal grafts, other ocular conditions for which the Boston KPro has been used include herpetic keratitis, aniridia, autoimmune ocular disorders, and pediatric corneal opacities. In the re...

متن کامل

Results with the Boston Type I keratoprosthesis after Acanthamoeba keratitis

Purpose To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. Observations Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I...

متن کامل

Boston type 1 keratoprosthesis: the university of california davis experience.

PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...

متن کامل

Treatment of Refractory Keratitis After a Boston Type I Keratoprosthesis With Corneal Collagen Cross-Linking.

PURPOSE To report a patient with refractory keratitis after a Boston type I keratoprosthesis treated with corneal collagen cross-linking (CXL). METHODS Case report. RESULTS A 29-year-old man with a history of chemical burn in the left eye underwent keratoprosthesis implantation. He developed infectious keratitis 4 months after surgery, which did not respond to topical antibiotics. The patie...

متن کامل

Improved centration of the type 1 Boston Keratoprosthesis in donor carrier tissue

The type 1 Boston Keratoprosthesis preparation requires a 3-mm central punch and an 8.5 mm or larger punch in the carrier tissue. These punches are ideally concentric, but we have found difficulty in achieving concentric punches when the larger punch is performed first. We present a modification in the preparation procedure to help minimize centration error.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 149 2  شماره 

صفحات  -

تاریخ انتشار 2010