Exercise echocardiography versus 201Tl single-photon emission computed tomography in evaluation of coronary artery disease. Analysis of 292 patients.

نویسندگان

  • M A Quiñones
  • M S Verani
  • R M Haichin
  • J J Mahmarian
  • J Suarez
  • W A Zoghbi
چکیده

BACKGROUND Exercise echocardiography (digital cine-loop technique) and 201Tl single-photon emission computed tomography (SPECT) were performed simultaneously in 292 patients being evaluated for coronary artery disease. METHODS AND RESULTS Pretreadmill and posttreadmill echocardiographic images of diagnostic quality were obtained in 289 patients, and the left ventricle was divided into anterior, inferior, and lateral regions. Any wall motion or perfusion abnormality observed within each region was classified as totally reversible, fixed, or partially reversible. Exercise echocardiography and SPECT were normal in 137 patients and abnormal in 118 (88% agreement). Equal numbers of regional abnormalities were detected by one test when missed by the other. The two tests had an 82% agreement in detecting the same type of finding within the regions analyzed. SPECT detected more reversible abnormalities than echocardiography, whereas echocardiography detected more fixed abnormalities than SPECT: Regions with a fixed abnormality by echocardiography frequently showed partial reversibility of a perfusion defect by SPECT: Nearly one third of regions with fixed perfusion defects by SPECT demonstrated normal resting function or reversible abnormalities by echocardiography. Sensitivity for coronary artery disease by angiography (greater than or equal to 50% diameter stenosis) in 112 patients was similar for the two tests, ranging from 58% and 61% (echocardiography and SPECT, respectively) for one-vessel disease to 94% for three-vessel disease. The specificities for echocardiography and SPECT were 88% and 81%, respectively. CONCLUSIONS Exercise echocardiography had a diagnostic accuracy comparable to that of SPECT for the detection of regional abnormalities produced by significant coronary artery disease. A greater number of abnormal regions were detected with the combined use of both tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Long-term prognostic value of exercise echocardiography compared with exercise 201Tl, ECG, and clinical variables in patients evaluated for coronary artery disease.

BACKGROUND The accuracy of exercise echocardiography and 201Tl single photon emission computed tomography (SPECT) is similar in the diagnosis of coronary artery disease (CAD). However, comparative data on long-term prognosis are lacking. METHODS AND RESULTS Clinical variables and exercise, echocardiographic, and 201Tl tomographic parameters were studied in 248 patients (age, 56+/-12 years [me...

متن کامل

Predicting recovery of severe regional ventricular dysfunction. Comparison of resting scintigraphy with 201Tl and 99mTc-sestamibi.

BACKGROUND Regional 201Tl activity after resting injection, imaged early and after redistribution, reflects viable myocardium and can predict improved isotope uptake as well as regional and global ventricular function after revascularization. 99mTc-sestamibi, a perfusion tracer with favorable imaging characteristics, has distinct kinetics compared with 201Tl, demonstrating minimal redistributio...

متن کامل

Quantitative angiographic measurements of isolated left anterior descending coronary artery stenosis. Correlation with exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile single-photon emission computed tomography.

OBJECTIVES This study sought to assess the value of quantitative coronary arteriography in predicting an ischemic response at exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile (mibi) single-photon emission computed tomography (SPECT) in patients with single-vessel disease of the left anterior descending coronary artery. BACKGROUND The relation between severity of coro...

متن کامل

Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

We tested the hypothesis that 99mTc 2-methoxy-isobutyl-isonitrile (99mTc MIBI), a new radiopharmaceutical for myocardial perfusion imaging, provides accurate noninvasive detection of coronary artery disease (CAD). Imaging in patients after exercise and at rest with 99mTc MIBI was compared with imaging after exercise and redistribution with 201Tl in 12 normal subjects and 38 patients with angiog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 1992