Low-energy g-ray spectra were collected from Am, Co, Ba, Au, Cs and U using a 3.4 3.4 5.7mm CdZnTe detector utilizing an insulated Frisch ring. The CdZnTe detector was fabricated from a single crystal and a copper shim was used as the Frisch collar. Room-temperature energy resolution of 1.45% full-width half-maximum (FWHM) was obtained for Cs at 661.7 keV without electronic correction. The detector fabrication process is described and the resulting energy spectra are discussed. The detector fabrication process is described and the resulting energy spectra are discussed. The detector full-energy-peak intrinsic efficiency is reported for different g-ray energies, specifically from Am, Co, Ba and Cs. r 2005 Elsevier B.V. All rights reserved. PACS: 29.30.Kv; 29.40. n
منابع مشابه
Angular response of a W-collimated room-temperature-operated CdZnTe Frisch collar spectrometer
The spatial resolution of a collimated CdZnTe Frisch collar detector was experimentally investigated for two different tungsten collimator designs using a Au gamma-ray source at 412 keV. A two-dimensional model for the detector–collimator–source geometry was developed and applied with some simplifying assumptions. The CdZnTe detector was fabricated from a single crystal using a copper shim as t...
متن کاملOptimization of virtual Frisch-grid CdZnTe detector designs for imaging and spectroscopy of gamma rays
In the past, various virtual Frisch-grid designs have been proposed for cadmium zinc telluride (CZT) and other compound semiconductor detectors. These include three-terminal, semi-spherical, CAPture, Frisch-ring, capacitive Frisch-grid and pixel devices (along with their modifications). Among them, the Frisch-grid design employing a noncontacting ring extended over the entire side surfaces of p...
متن کاملNew Results from Performance Studies of Frisch-Grid CdZnTe Detectors
New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...
متن کاملCharge Collection Characteristics of Frisch Collar CdZnTe Gamma Ray Spectrometers
A collimated Au source was used to determine the charge collection efficiency (CCE) at several locations along the length of a 3.4 x 3.4 x 5.5 mm CdZnTe bar detector both in planar configuration and with Frisch collars of varying length. For each configuration, a 0.50 mm long region spanning the width of the device was irradiated with 411 keV gamma rays produced by a neutron activated gold foil...
متن کاملGeometrically weighted semiconductor Frisch grid radiation spectrometers
A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correctio...