A new manipulator structure for power-assist devices
نویسندگان
چکیده
Purpose – This paper introduces a new manipulator structure to configure power-assist devices in order to protect operators from musculoskeletal disorders. The mechanical structure and the control system are presented, along with their main features. Design/methodology/approach – The new structure is designed under the criterion of minimizing the torques required for handling payloads of up to 75 kg in an easily controlled system. Findings – A new structure is provided, based on electrical AC motors and capable of handling high payloads yet exerting low motor torque. Originality/value – The application of the criterion of minimizing the required torques to handle heavy payloads produced a new manipulator structure. This structure is patent protected.
منابع مشابه
Pneumatic Soft Actuator for Human Assist Technology
In the coming advanced age society, an innovative technology to assist the activities of daily living of elderly and disabled people and the heavy work in nursing is desired. To develop such a technology, an actuator safe and friendly for human is required. It should be small, lightweight and has to provide a proper softness. We call such an actuator soft actuator. A pneumatic rubber artificial...
متن کاملDynamic Modeling and Construction of a New Two-Wheeled Mobile Manipulator: Self-balancing and Climbing
Designing the self-balancing two-wheeled mobile robots and reducing undesired vibrations are of great importance. For this purpose, the majority of researches are focused on application of relatively complex control approaches without improving the robot structure. Therefore, in this paper we introduce a new two-wheeled mobile robot which, despite its relative simple structure, fulfills the req...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملLocating of Series FACTS Devices for Multi-Objective Congestion Management Using Components of Nodal Prices
Congestion and overloading for lines are the main problems in the exploitation of power grids. The consequences of these problems in deregulated systems can be mentioned as sudden jumps in prices in some parts of the power system, lead to an increase in market power and reduction of competition in it. FACTS devices are efficient, powerful and economical tools in controlling power flows through ...
متن کاملOptimal Placement and Sizing of TCSC & SVC for Improvement Power System Operation using Crow Search Algorithm
Abstract: The need for more efficient power systems has prompted the use of a new technologies includes Flexible AC transmission system (FACTS) devices. FACTS devices provides new opportunity for controlling the line power flow and minimizing losses while maintaining the bus voltages within a permissible limit. In this thesis a new method is proposed for optimal placement and sizing of Thyristo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Industrial Robot
دوره 37 شماره
صفحات -
تاریخ انتشار 2010