Bi-layer Diaphragm Walls: Structural and Sectional Analysis
ثبت نشده
چکیده
The bi-layer diaphragm wall, a new slurry wall type designed to cope with the problem of watertightness is studied in this paper. These walls consist of two bonded concrete layers, the first, a conventional Reinforced Concrete (RC) diaphragm wall, and the second, a Sprayed Steel Fibre Reinforced Concrete (SFRC). The main objective of this paper is to analyze the structural and sectional behaviour of these walls. A study in the form of an uncoupled structuralsection analysis based on various hypothetical cases of bi-layer diaphragm walls was performed to fulfil the objective. It is concluded that there exists a potential of reduction in the reinforcement of the RC layer through the structural use of the SFRC layer. However, when the reduction is quantified, even though a reduction of between 3.2% and 1.7% in the RC reinforcement is confirmed, it appears insufficient to offer a cost-effective solution. Nonetheless, the system becomes a promising solution when particular conditions are taken into account, such as basement space limitations.
منابع مشابه
Investigation of the Rigidity of Floor Diaphragms on the Behavior of Concrete Tall Buildings with Staggered Shear Walls under Lateral Loading
In most cases, structural engineers assume a concrete floor to be a rigid diaphragm. Although this simplification is in most cases acceptable, it should be noted that such an assumption may be distrusted due to certain problems. Concrete structures with staggered shear walls are among those whose analysis should be conducted with special concern for the behavior of their floor diaphragms. Howev...
متن کاملInvestigation of the Rigidity of Floor Diaphragms on the Behavior of Concrete Tall Buildings with Staggered Shear Walls under Lateral Loading
In most cases, structural engineers assume a concrete floor to be a rigid diaphragm. Although this simplification is in most cases acceptable, it should be noted that such an assumption may be distrusted due to certain problems. Concrete structures with staggered shear walls are among those whose analysis should be conducted with special concern for the behavior of their floor diaphragms. Howev...
متن کاملFabrication of polyimide bi-stable diaphragms using oxide compressive stresses for the field of buckle MEMS
In this paper we develop vacuum-actuated polyimide bi-stable actuators using buckled diaphragms for applications in the field of MEMS. The fabrication process involves a single mask step and DRIE etch step to fabricate the buckled bi-stable diaphragms. Compressive stresses in a companion thermal oxide layer provide pre-stress in the polyimide mechanical films that initiates diaphragm buckling u...
متن کاملNumerical Framework for Seismic Collapse Assessment of Rigid Wall-flexible Diaphragm Structures
This study focuses on the development of a two dimensional (2D) simplified numerical framework of rigid wall-flexible diaphragm (RWFD) structures that can be used to validate seismic design approaches. This type of low-rise industrial buildings, which is widely used in North America, incorporates rigid inplane concrete or masonry walls and flexible in-plane wood, steel or “hybrid” roof diaphrag...
متن کاملInvestigating the Longitudinal Optical Conductivity in Three-Layer Graphene Systems with Composes Mono-Bi-Bi and Bi-Mono-Bi and Bi-Bi-Mono
The longitudinal optical conductivity is the most important property for graphene-baseddevices. So investigating this property for spatially separated few-layer graphene systems analytically and numerically is the main purpose of our study. Each layer can be mono- or bi-layer graphene. The density-density correlation function has been screened by the dielectric function using the random p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -