Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating

نویسندگان

  • Manijeh Vafa Homann
  • Dorota Johansson
  • Håkan Wallen
  • Javier Sanchez
چکیده

Central line associated bloodstream infections (CLABSIs) are a serious cause of morbidity and mortality induced by the use of central venous catheters (CVCs). Nobel metal alloy (NMA) coating is an advanced surface modification that prevents microbial adhesion and growth on catheters and thereby reduces the risk of infection. In vitro microbiological analyses have shown up to 90% reduction in microbial adhesion on coated CVC compared to uncoated ones. This study aimed to assess the blood compatibility of NMA-coated CVC according to ISO 10993-4. Hemolysis, thrombin-antithrombin (TAT) complex, platelet counts, fibrin deposition, and C3a and SC5b-9 complement activation were analyzed in human blood exposed to the NMA-coated and control CVCs using a Chandler-loop model. NMA-coated CVC did not induce hemolysis and fell in the "nonhemolytic" category according to ASTM F756-00. Significantly lower amounts of TAT were generated and less fibrin was deposited on NMA-coated CVC than on uncoated ones. Slightly higher platelet counts and lower complement markers were observed for NMA-coated CVC compared to uncoated ones. These data suggest that the NMA-coated CVC has better ex vivo blood compatibility compared to uncoated CVC. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1359-1365, 2016.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of central venous catheters coated with a noble metal alloy-A randomized clinical pilot study of coating durability, performance and tolerability.

The use of Central Venous Catheters (CVCs) commonly results in complications. Coatings with silver or metal alloys can reduce the risk associated with the use of CVC. We have evaluated the durability of a noble metal coated CVC (the Bactiguard Infectious Protection, BIP CVC) and compared with an uncoated CVC for clinical tolerability (Adverse Events, AEs) and performance, in order to create a b...

متن کامل

Adhesion of Streptococcus Mutans to Zirconia, Enamel, IPS Empress II, Noble Alloy and Base-metal: An In-Vitro Comparative Study

Introduction: With increased usage of restorative materials, dentists are more concerned in choosing a suitable material with lower adhesion of pathogens like streptococci. This comparative in vitro study aimed to compare adhesion of streptococcus mutans to zirconia, IPS Empress II, noble alloy, and base-metal. Materials and Methods: In this descriptive study, 50 specimens (5 mm diameter disk ...

متن کامل

Survey of a Practical Approach to Central Venous Catheterization in Pediatric Patients

Background Central venous catheter (CVC) is used for measuring hemodynamic variables, transfusion of blood, fluids and medications when peripheral vascular lack sufficiency. Unfortunately CVC is associated with many complications ranging from anxiety and discomfort for the patient to severe mechanical side effects such as arterial lacerations, pleural and pericardial injury as well as infection...

متن کامل

Skin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections

Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...

متن کامل

Catheter-related candidemia and identification of causative Candida species in patients with cardiovascular disorder

Background and Purpose: Catheter-related blood circulation infection is the most dangerous and serious side-effects of vascular catheters, which leads to the enhancement of the costs, mortality, and hospital stay duration, especially in the Intensive Care Unit. Regarding this, the aim of the current study was to identify the prevalence of catheter-induced candidemia in the Tehran Heart Center, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 104  شماره 

صفحات  -

تاریخ انتشار 2016