SU-E-T-437: Interfractional Dosimetric Verification of Lung Patients Treated by Passive Double Scattering Proton Radiotherapy.

نویسندگان

  • S Tang
  • L Yin
  • R Rengan
  • P James
  • S Hahn
  • S Both
چکیده

PURPOSE Proton radiotherapy, with the ability to confine the dose at desired depth, can potentially benefit lung tumor patients by significantly sparing the healthy lung tissue. However, the superior proton dose distribution could be affected by tumor shrinkage due to the quick response and by motion especially related to the respiration. Thus the treatment should be frequently verified and be adjusted accordingly if necessary to achieve the initial treatment goal. MATERIAL AND METHODS A cohort of 20 patients were selected from lung patients treated with passive proton radiotherapy. All those patients were evaluated via 4D-CT scans and found to have tumor motion less than 1 cm. The internal target volumes (ITV) were derived based on the full inspiration and expiration phases. The average of the 4D-CT scan, full inspiration and expiration phases were used for the initial treatment planning. The planning objective was 95% of the prescription dose to at least 95% volume of the ITV. Bi-weekly verification 4D-CT scans were performed to assess the robustness of the initial treatment plan and no replanning was required for target dose variations less then 3%. RESULTS Compared with the initial treatment plan, the standard deviations of target coverage on inspiration, expiration, and average verification CT scans are within 3% for all the patients, with the maximum difference up to 7%. No statistically significant differences were found among the initial and verification plans (p>0.1). The percentage deviations of OAR sparing were highly variable, e.g., up to 40% for mean lung dose, 100% for mean heart dose, 50% for max cord dose, particularly for OARs receiving small amount of doses. However, the absolute dose deviations are all with OAR's tolerance. CONCLUSION Overall, the passive double scattering proton modality allows for robust proton treatment planning and delivery to treat the lung tumors with limited motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Planning for a Patient Treated in Decubitus Position with Proton Pencil Beam Scanning Radiotherapy

A challenging case was reported for a patient treated in decubitus position with proton pencil beam scanning. A regular robust plan with the consideration of the uncertainties of translational alignment and range accuracy cannot ensure the target coverage as revealed in two verification computed tomography (CT) scans during the first week of the treatment. The irreproducibility of daily alignme...

متن کامل

An in-silico comparison of proton beam and IMRT for postoperative radiotherapy in completely resected stage IIIA non-small cell lung cancer

INTRODUCTION Post-operative radiotherapy (PORT) for stage IIIA completely-resected non-small cell lung cancer (CR-NSCLC) has been shown to improve local control; however, it is unclear that this translates into a survival benefit. One explanation is that the detrimental effect of PORT on critical organs at risk (OARs) negates its benefit. This study reports an in-silico comparative analysis of ...

متن کامل

SU-E-T-579: Dosimetric Benefits of Online Adaptive Replanning for Post-Operative Radiation Therapy of Prostate Bed.

PURPOSE To demonstrate the dosimetric benefits of using an online adaptive replanning scheme to address interfractional variations in radiotherapy of prostate bed. METHODS We have previously developed an online adaptive replanning tool (RealART, Prowess Inc.) aiming to address interfractional variations including organ deformation and rotation. Using this tool, we analyzed a total of 102 dail...

متن کامل

Interfractional Variations of Tumor Centroid Position and Tumor Regression during Stereotactic Body Radiotherapy for Lung Tumor

PURPOSE To determine interfractional changes of lung tumor centroid position and tumor regression during stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS 34 patients were treated by SBRT in 4-5 fractions to a median dose of 50 Gy. The CT scans acquired for verification were registered with simulation CT scans. The gross target volume (GTV) was contoured on all verification CT...

متن کامل

The effects of motion on the dose distribution of proton radiotherapy for prostate cancer

Proton radiotherapy of the prostate basal or whole seminal vesicles using scattering delivery systems is an effective treatment of prostate cancer that has been evaluated in prospective trials. Meanwhile, the use of pencil beam scanning (PBS) can further reduce the dose in the beam entrance channels and reduce the dose to the normal tissues. However, PBS dose distributions can be affected by in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part16  شماره 

صفحات  -

تاریخ انتشار 2012