Biomechanical study of a novel self-locking plate system for anterior cervical fixation

نویسندگان

  • Lifeng Lao
  • Qianyi Li
  • Guibin Zhong
  • Chao Song
  • Yuanchao Li
  • Mingze Xu
  • Zude Liu
چکیده

BACKGROUND Anterior cervical plate had developed continuously, and this study aimed to assess the biomechanics of a novel self-locking plate system for anterior cervical fixation designed by ourselves. METHODS Twelve anterior cervical plates (i.e., six novel plates and six DePuy plates) were subjected to a pull-out test and a fatigue test. In addition, 12 C1-T1 cervical spine specimens underwent anterior cervical corpectomy and C5 fusion using six novel plates and six DePuy plates. Pre- and postoperative range of motion, load-displacement, axial stiffness, torque, and twisting stiffness were compared. RESULTS No differences in maximum pull-out force, relative displacement, or energy absorption were observed between the DePuy plates and the novel plates (P >0.05). The novel plate system could bear an average of 5.6 × 105 times of loading, while the DePuy plate could bear 5.4 × 105 times of loading. The fatigue strengths of the new plate system and the DePuy plate were 490.75 and 485.86 MPa, respectively. No differences in fatigue life or strength were observed between the two types of plates. Cervical spine stability increased significantly after internal fixation. No differences in range of motion, load-displacement, axial stiffness, torque, or twisting stiffness were observed between the novel self-locking plate and the DePuy plate (P >0.05). CONCLUSIONS Compared to the DePuy plate, the novel anterior cervical self-locking plate system described here has good strength and fastening ability, allowing it to provide sufficient biomechanical stability. Further clinical assessment of this system is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of Anterior Cervical Spine Fixation Devices

The anterior cervical plate fixation systems have been widely used in treatment of complex spinal disorders such as traumatic lesion, disc hernination, tumor, spondylosis, arthritides, and others. Combined with bone graft or other fusion techniques the satisfactory outcomes were higher than 88% (Clements 1990, Naito 1993,Bose 1998, Schneeberger 1999). Among the screw plate fixation systems, Cas...

متن کامل

Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines.

OBJECTIVE To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN In vitro biomechanical evaluation. ANIMALS Cadaveric canine C4-C7 cervical spines (n = 9). METHODS Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while...

متن کامل

A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.

A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in t...

متن کامل

Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis

BACKGROUND The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws. We hypothesized that a locking plate applied to the anterior column of a transverse acetabular fracture would create a construct that is more rigid than a non-locking p...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014