Combining Growcut and Temporal Correlation for IVUS Lumen Segmentation
نویسندگان
چکیده
The assessment of arterial luminal area, performed by IVUS analysis, is a clinical index used to evaluate the degree of coronary artery disease. In this paper we propose a novel approach to automatically segment the vessel lumen, which combines model-based temporal information extracted from successive frames of the sequence, with spatial classi cation using the Growcut algorithm. The performance of the method is evaluated by an in vivo experiment on 300 IVUS frames. The automatic and manual segmentation performances in general vessel and stent frames are comparable. The average segmentation error in vessel, stent and bifurcation frames are 0.17±0.08 mm, 0.18±0.07 mm and 0.31±0.12 mm respectively.
منابع مشابه
Conditional Random Fields for image segmentation in Intravascular Ultrasound
We present a Conditional Random Fields based approach for segmenting Intravascular Ultrasound (IVUS) images. The presented method uses a contextual discriminative graphical model to deal with the presence of distortions and artifacts in IVUS images, that turns the segmentation of interesting regions into a difficult task. An accurate lumen segmentation on IVUS longitudinal images is achieved.
متن کاملAutomatic Segmentation of Lumen in Intravascular Ultrasound Images Using Fuzzy Clustering and Active Contours
Intravascular ultrasound (IVUS) imaging constitutes a widely used technique for coronary heart disease diagnosis and management of arterial atherosclerosis. The identification of lumen and media-adventitia boundaries in IVUS images is necessary for an efficient quantitative assessment of atherosclerotic plaques. In this paper, a new automated approach for lumen border detection is proposed. Thi...
متن کاملA Novel 3D Segmentation Method of the Lumen from Intravascular Ultrasound Images
In this paper a novel method that automatically detects the lumenintima border on an intravascular ultrasound sequence (IVUS) is presented. First, a 3D co-occurrence matrix was used to efficiently extract the texture information of the IVUS images through the temporal sequence. By extracting several co-occurrence matrices a complete characterization feature space was determined. Secondly, using...
متن کاملStandardized evaluation methodology and reference database for evaluating IVUS image segmentation
This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, m...
متن کاملImage analysis techniques for automated IVUS contour detection.
Intravascular ultrasound (IVUS) constitutes a valuable technique for the diagnosis of coronary atherosclerosis. The detection of lumen and media-adventitia borders in IVUS images represents a necessary step towards the reliable quantitative assessment of atherosclerosis. In this work, a fully automated technique for the detection of lumen and media-adventitia borders in IVUS images is presented...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011