Does PEEK/HA Enhance Bone Formation Compared With PEEK in a Sheep Cervical Fusion Model?

نویسندگان

  • William R. Walsh
  • Matthew H. Pelletier
  • Nicky Bertollo
  • Chris Christou
  • Chris Tan
چکیده

BACKGROUND Polyetheretherketone (PEEK) has a wide range of clinical applications but does not directly bond to bone. Bulk incorporation of osteoconductive materials including hydroxyapatite (HA) into the PEEK matrix is a potential solution to address the formation of a fibrous tissue layer between PEEK and bone and has not been tested. QUESTIONS/PURPOSES Using in vivo ovine animal models, we asked: (1) Does PEEK-HA improve cortical and cancellous bone ongrowth compared with PEEK? (2) Does PEEK-HA improve bone ongrowth and fusion outcome in a more challenging functional ovine cervical fusion model? METHODS The in vivo responses of PEEK-HA Enhanced and PEEK-OPTIMA® Natural were evaluated for bone ongrowth in the form of dowels implanted in the cancellous and cortical bone of adult sheep and examined at 4 and 12 weeks as well as interbody cervical fusion at 6, 12, and 26 weeks. The bone-implant interface was evaluated with radiographic and histologic endpoints for a qualitative assessment of direct bone contact of an intervening fibrous tissue later. Gamma-irradiated cortical allograft cages were evaluated as well. RESULTS Incorporating HA into the PEEK matrix resulted in more direct bone apposition as opposed to the fibrous tissue interface with PEEK alone in the bone ongrowth as well as interbody cervical fusions. No adverse reactions were found at the implant-bone interface for either material. Radiography and histology revealed resorption and fracture of the allograft devices in vivo. CONCLUSIONS Incorporating HA into PEEK provides a more favorable environment than PEEK alone for bone ongrowth. Cervical fusion was improved with PEEK-HA compared with PEEK alone as well as allograft bone interbody devices. CLINICAL RELEVANCE Improving the bone-implant interface with a PEEK device by incorporating HA may improve interbody fusion results and requires further clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Biomechanical stability of a bioabsorbable self-retaining polylactic acid/nano-sized β-tricalcium phosphate cervical spine interbody fusion device in single-level anterior cervical discectomy and fusion sheep models

PURPOSE The aim of this study was to investigate the biomechanical stability provided by a novel, polylactic acid/nano-sized, β-tricalcium phosphate, bioabsorbable, self-retaining cervical fusion cage (BCFC). METHODS Quasistatic nonconstraining torques (maximum 1.5 NM) induced flexion, extension, lateral bending (±1.5 NM), and axial rotation (±1.5 NM) on 32 sheep cervical spines (C2-C5). The ...

متن کامل

مقایسه روند بالینی بیماران مبتلا به ضایعات دیسکال گردنی در روش‌های دیسککتومی قدامی گردن بدون فیوژن، همراه با فیوژن استخوانی از کرست ایلیاک و استفاده از کیج PEEK

  Background & Objective : The preferred Selection of the anterior cervical discectomy alone, with iliac crest bone graft fusion and using the PEEK cage is still in controversial in degenerative disc disease. The aim of this study is comparing them on radiographic and clinical results. Materials & Methods: The all consecutive patients in the three hospitals in Tehran between the 2000 up to the ...

متن کامل

In vivo experimental study of anterior cervical fusion using bioactive polyetheretherketone in a canine model

BACKGROUND Polyetheretherketone (PEEK) is a widely accepted biomaterial, especially in the field of spinal surgery. However, PEEK is not able to directly integrate with bone tissue, due to its bioinertness. To overcome this drawback, various studies have described surface coating approaches aimed at increasing the bioactivity of PEEK surfaces. Among those, it has been shown that the recently de...

متن کامل

Cold-spray coating of hydroxyapatite on a three-dimensional polyetheretherketone implant and its biocompatibility evaluated by in vitro and in vivo minipig model.

PEEK is a bioinert material that does not chemically bind to native bone tissue and thus formation of natural bone-like hydroxyapatite (HA) coating layer on PEEK has been an important challenge to improve biocompatibility and to preserve mechanical property of PEEK. Among various coating techniques, cold-spray coating method is suitable to form stable HA coating layer on PEEK while maintaining ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 474  شماره 

صفحات  -

تاریخ انتشار 2016