Implementation of Bubble CPAP in a Rural Ugandan Neonatal ICU.
نویسندگان
چکیده
BACKGROUND Respiratory distress is a leading cause of neonatal death in low-income and middle-income countries. CPAP is a simple and effective respiratory support modality used to support neonates with respiratory failure and can be used in low-income and middle-income countries. The goal of this study was to describe implementation of the Silverman-Andersen respiratory severity score (RSS) and bubble CPAP in a rural Ugandan neonatal NICU. We sought to determine whether physicians and nurses in a low-income/middle-income setting would assign similar RSS in neonates after an initial training period and over time. METHODS We describe the process of training NICU staff to use the RSS to assist in decision making regarding initiation, titration, and termination of bubble CPAP for neonates with respiratory distress. Characteristics of all neonates with respiratory failure treated with bubble CPAP in a rural Ugandan NICU from January to June 2012 are provided. RESULTS Nineteen NICU staff members (4 doctors and 15 nurses) received RSS training. After this, the Spearman correlation coefficient for respiratory severity scoring between doctor and nurse was 0.73. Twenty-one infants, all < 3 d of age, were treated with CPAP, with 17 infants starting on the day of birth. The majority of infants (16/21, 76%) were preterm, 10 (48%) were <1,500 g (birthweight), and 13 (62%) were outborn. The most common diagnoses were respiratory distress syndrome (16/21, 76%) and birth asphyxia (5/21, 24%). The average RSS was 7.4 ± 1.3 before starting CPAP, 5.2 ± 2.3 after 2-4 h of CPAP, 4.9 ± 2.7 after 12-24 h of CPAP, and 3.5 ± 1.9 before CPAP was discontinued. Duration of treatment with CPAP averaged 79 ± 43 h. Approximately half (11/21, 52%) of infants treated with CPAP survived to discharge. CONCLUSIONS Implementing bubble CPAP in a low-income/middle-income setting is feasible. The RSS may be a simple and useful tool for monitoring a neonate's respiratory status and for guiding CPAP management.
منابع مشابه
Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates
Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...
متن کاملComparison of the Therapeutic Effects of Bubble CPAP and Ventilator CPAP on Respiratory Distress Syndrome in Premature Neonates
Background: Respiratory distress syndrome is one of the main complications associated with low birth weight, and a main cause of mortality in premature neonates. The present study aimed to compare the efficacy of ventilator continuous positive airway pressure (CPAP) and bubble CPAP in the treatment of respiratory distress syndrome (RDS) in premature neonates. Methods: This randomized controlled...
متن کاملBubble CPAP: not all bubbling is good bubbling.
Since its introduction over 30 years ago,1 bubble CPAP has become an important part of the management of neonatal respiratory distress syndrome. Similar to “ventilatorderived” or “machine-derived” CPAP devices, bubble CPAP devices apply pressure to the neonatal respiratory system via nasal prongs placed into the infant’s nostrils, forming a tight seal to minimize leak. On the other hand, bubble...
متن کاملPublications relating the use of CPAP in developing countries
To describe the implementation of bubble-CPAP in a referral hospital in a developing country and to investigate: the feasibility of nurses implementing bubble-CPAP and the impact of bubble-CPAP on need for mechanical ventilation and mortality. Retrospective evaluation of prospectively collected data from two time periods: 18 months before and 18 months after the introduction of bubble-CPAP. The...
متن کاملBubble CPAP for respiratory distress syndrome in preterm infants.
OBJECTIVES To ascertain the immediate outcome of preterm infants with respiratory distress syndrome (RDS) on Bubble CPAP and identify risk factors associated with its failure. STUDY DESIGN Prospective analytical study. SUBJECTS Inborn preterm infants (gestation 28 to 34 weeks) admitted to the NICU with respiratory distress and chest X ray suggestive of RDS. INTERVENTION Bubble CPAP with b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 60 3 شماره
صفحات -
تاریخ انتشار 2015