Stress distribution in retentive arms of combination clasps used on premolars.

نویسندگان

  • Liliana Sandu
  • Florin Topala
  • Sorin Porojan
چکیده

INTRODUCTION Stresses resulting from cast clasp arms during insertion and the removal of removable partial dentures are the main causes of deformations or fractures. Therefore, achieving clasp designs producing less stress is very important. OBJECTIVE Retentive clasp arms used for premolars were investigated through the reverse engineering approach. The aim was to determine stress distribution in oval and half-oval clasps cross-sections in order to analyse biomechanical behavior. MATERIAL AND METHODS Purposely designed experimental three-dimensional (3D) models of the clasp arms were constructed on the buccal surface of an upper first premolar, to be used for structural simulations. 3D teeth models obtained after laser scanning were used as a support for retentive clasp arms modeling. Parameters of the clasp arms like length, thickness and cross-section were considered for the simulation of stainless steel wires. A concentrated load of 5 N was applied at the inner tip of the clasp arm. RESULTS A precise model of the coronal buccal surface of an upper first premolar was generated. This model was a useful tool in designing stainless steel clasp arms of different thickness and cross-section. In all cases, high stress values were located on the inner surface of the clasp arm, in the part located above the height of the contour. A similar bending stiffness was observed between the half-round cross-section design with a diameter of 1 mm and the round cross-section design with a diameter between 0.6 and 0.7 mm. CONCLUSIONS This in vitro study demonstrated that the reverse engineering approach and structural analyses provide a powerful tool for designing clasps and visualizing fracture risk areas and for choosing the adequate cross-section for each case. Within the limitations of this study, it was suggested that, on premolars, the biomechanical performance of half-round cross-sections for the retentive arms may be higher than round sections of clasp arms showing similar mechanical stiffness.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress analysis of clasps made of glass fiber-reinforced composite material using three-dimensional finite element method: influence of shape in cross and longitudinal sections of circumferential clasp arms.

The purpose of this study was to investigate the effects of different cross-sectional shapes and presence of taper on stress distribution in clasp arms made of glass fiber-reinforced composite (FRC) material. Stress analysis of clasps was performed under a constant load (5 N) using a three-dimensional finite element method with due consideration to the anisotropy of unidirectional FRC material....

متن کامل

Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture.

BACKGROUND/AIM Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profi...

متن کامل

Finite Element Analysis of Stress Distribution in the Cast Clasps, Direct Retainers of a Removable Partial Denture

Objectives: The purpose of this study was to evaluate the stress distribution in the critical components of the removable partial denture the cast clasps. Materials andmethod:The three-dimensional models of the clasps were generated using three-dimensional measurements and investigated during loading, using the finite element stress analysis. Results:Although the loading influences the stressdi...

متن کامل

Retentive forces and fatigue resistance of thermoplastic resin clasps.

OBJECTIVES The objective of this study was to evaluate the retentive force of clasps made from three thermoplastic resins and cobalt-chromium (CoCr) alloy by the insertion/removal test simulating 10 years use. METHODS On standardized premolar metal crowns 112 clasps were fabricated, including 16 CoCr (1.0 mm thick) clasps and 32 clasps (1.0 or 1.5 mm thick) from each of the following thermopl...

متن کامل

Using the path of insertion to retain a partial denture.

To resist these forces, dentistry has developed a wide variety of mechanical attachments that include circumferential clasps, bar clasps, indirect retainers, ring clasps, reverse loop clasps, hybrid clasps; and an assortment of precision attachments that include springs, flanges, snaps, latches, plungers and retentive arms. Despite dramatic differences in design, virtually all of these retentio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied biomaterials & biomechanics : JABB

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2010