Fungal Contamination of Air in the Department of Haematology

نویسندگان

  • Urszula Nawrot
  • Lidia Usnarska-Zubkiewicz
  • Magdalena Pajączkowska
  • Grażyna Mokracka-Latajka
  • Kazimierz Kuliczkowski
  • Jadwiga Nowicka
چکیده

The aim of this study was to test the air in a single hospital department for fungal contamination. The department included three fully protected rooms with laminar air flow, comprising a bone marrow transplant unit (BMTU) and eleven naturally ventilated patient rooms of a haematology unit (HAEMU). Air samples were taken with an IDEAL air sampler (bioMerieux) on Sabouraud dextrose agar plates. The concentration of fungi in the air of the HEPA-filtered rooms of the BMTU ranged from 0-75 CFU/m. Penicillium and Cladosporium were dominant among the fungal biota in the whole department. Of aspergilli, A. fumigatus was prevalent and seasonal increases in the frequencies of A. clavatus and A. niger isolation were observed. The detection of potentially pathogenic species of Aspergillus and Mucor in the BMTU and an increased concentration of Aspergillus in the HAEMU (up to 200 CFU/m) instigated the introduction of additional preventive measure besides routine disinfection, namely an exchange of the HEPA filters in the BMTU and the installation of equipment based on multifunctional ion technology in the HAEMU. In a subsequent examination, a diminished number of fungi in the air was observed. During the study, 2 cases of proven and 3 of probable aspergillosis (according to EORT criteria) were noted. There was no link observed between the higher concentration of Aspergillus detected in the hospital air and the development of the infection. The authors conclude that hospital air examination can be helpful in indicating problems with hospital air facilities, enabling the introduction of procedures improving air quality and subsequently diminishing the risk of nosocomial

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Monitoring of Fungal Contamination in Indoor Air of Two Hospitals in Shiraz

Introduction: Hospitals, as one of the important elements in the health system, play an important role in patient’s health. Fungi are one of the effective parameters on indoor air quality. This study aimed to compare of fungal contamination of two hospitals in Shiraz City. Materials and Methods: Sampling was conducted based on NIOSH 0800 standard (1.5 meters above the ground level with one sta...

متن کامل

Monitoring the air fungal contamination load in two educational hospitals in Sanandaj, Iran

Opportunistic fungal pathogens are known to increase infection in the health care workers and patients with immune deficiency. This study aimed to investigate the qualitative and quantitative airborne fungal contamination load in two Sanandaj hospitals. In this cross-sectional study, 112 biological samples from 15 different hospital wards were collected for 6 months by using the single-stage An...

متن کامل

The Rate of Airborne Fungal Contamination in Yazd Textile Factories in 2007

Background & Aims: Fungi are among the most important biological agents in air pollution. Textile factories are known as high risk places for contamination with fungal spores and metabolites. Since Yazd is one of the most important textile industry centers, this study was conducted to determine the concentration and types of airborne fungi in Yazd textile factories. Methods: A total of 235 indo...

متن کامل

Isolation and characterization of mycoflora of chicken hatcheries in Mazandaran province, north of Iran

Fungal infections cause significant economic losses in the poultry industry either due to their direct infectious nature or due to mycotoxins production. Hatchery contamination with fungi can threaten chicken health. In this regard, geographical and seasonal distributions of airborne fungal contamination of 25 hatcheries in Mazandaran province, northern Iran, were investigated using an open pla...

متن کامل

Concurrence of Nosocomial Infections with Microorganisms Spreading in the Air of Hospital Wards

Abstract Background and objectives: A Nosocomial infection is one of the Leading problems causing high mortality among hospitalized patients. This study aimed at confirming the concurrence of Nosocomial infections with microorganisms spreading in the air of hospital wards. Material and Methods: This study was conducted in 2009 at ValieAsr Hospital in Tehran, Iran. The Samples were taken from th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010