Release of vancomycin and gentamicin from a contact lens versus a fibrin coating applied to a contact lens.

نویسندگان

  • Alex J T Hyatt
  • Madhavan S Rajan
  • Keith Burling
  • Matthew J Ellington
  • Alessia Tassoni
  • Keith R Martin
چکیده

PURPOSE To develop a contact lens capable of releasing antibiotics for a minimum of 8 hours for the treatment of bacterial keratitis. METHODS Fibrin gel was loaded with vancomycin or gentamicin and then shaped into a curved disc. The disc was then used to coat the surface of a commercial contact lens or was sealed between two lenses. Separate contact lenses were soaked in solutions of vancomycin or gentamicin. The in vitro release kinetics for each system was determined using PBS at 37°C and a particle-enhanced turbidimetric inhibition immunoassay. The bioactivity of the antibiotics released from the fibrin was confirmed by using a microbiological assay. RESULTS Vancomycin and gentamicin were released at similar rates from soaked contact lenses and a coating of fibrin gel; however, the amounts of antibiotic delivered by the two systems differed considerably. The fibrin coating released over three times more gentamicin but less than one-fifth that of the lenses soaked in vancomycin. When fibrin was encapsulated between two contact lenses, significantly more controlled release was observed. For all systems, bactericidal amounts of vancomycin and gentamicin were released throughout the three-day testing period. CONCLUSIONS As a delivery system, fibrin gel loaded with gentamicin performs better than contact lenses soaked in gentamicin. The opposite is true for vancomycin, where soaked lenses outperform fibrin gel. These systems could potentially be used as a treatment for bacterial keratitis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

امکان استفاده از آنزیم EcoR1 در طبقه بندی سویه های اکانتامبای ایزوله شده از التهاب قرنیه

Acanthamoeba keratitis is increasingly being diagnosed among people who wear thrapeutic and cosmetic contact lenses. The chain of events is thought to begin with contamination of the contact lens storage cases with Acanthamoeba from household or mains water supplies. If bacteria contamination is also present then these amoebas can multiply by ingesting the bacteria as a food source. If the cont...

متن کامل

Sensitivity Pattern of Bacteria Isolated from Contact Lens Wearers in the Faculty of Pharmacy, Karachi University Student Population

Contact lens wearers are at great risk of developing microbial keratitis because of incorrect usages and unhygienic maintenance of contact lenses. Therefore, the present study was planned to provide data that will be helpful in selecting the anti-microbial to cure microbial keratitis. One hundred bacterial isolates from conjunctiva of contact lenses wearer were isolated, identified and subjecte...

متن کامل

Sensitivity Pattern of Bacteria Isolated from Contact Lens Wearers in the Faculty of Pharmacy, Karachi University Student Population

Contact lens wearers are at great risk of developing microbial keratitis because of incorrect usages and unhygienic maintenance of contact lenses. Therefore, the present study was planned to provide data that will be helpful in selecting the anti-microbial to cure microbial keratitis. One hundred bacterial isolates from conjunctiva of contact lenses wearer were isolated, identified and subjecte...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2012