Left ventricular diastolic function after electrical cardioversion of atrial fibrillation.
نویسندگان
چکیده
In chronic atrial fibrillation (AF) left ventricular function may gradually diminish as a result of an intrinsic tachycardiomyopathy. This tachycardia induced cardiomyopathy is characterised by decreased systolic function, ventricular dilation, and raised ventricular filling pressures. In such patients left ventricular systolic function may gradually improve after electrical cardioversion. Little is known about left ventricular diastolic function in AF. In animal models with chronic rapid pacing induced cardiomyopathy, systolic dysfunction is accompanied by an increased diastolic wall stress and impaired myocardial relaxation. In addition, recovery from supraventricular tachycardia induced cardiomyopathy in animal models is associated with hypertrophy, reduced myocardial blood flow, and diastolic dysfunction. Whether the same changes in diastolic left ventricular function hold true for humans with AF remains to be investigated. The present study was performed to investigate diastolic filling in patients with AF after successful cardioversion compared to a control group.
منابع مشابه
Role of Left Ventricular Diastolic Dysfunction in Predicting Atrial Fibrillation Recurrence after Successful Electrical Cardioversion.
The role of left ventricular (LV) diastolic dysfunction in predicting atrial fibrillation (AF) recurrence after successful electrical cardioversion is largely unknown. Studies suggest that there may be a link between abnormal LV compliance and the initial development, and recurrence of AF after electrical cardioversion. Although direct-current cardioversion (DCCV) is a well-established and high...
متن کاملChanges in Left Ventricular Filling in Patients with Persistent Atrial Fibrillation
BACKGROUND Former studies showed possible interrelationship between altered ventricular filling patterns and atrial fibrillation (AF). HYPOTHESIS Long term persistent AF has a negative impact on left ventricular filling in patients with preserved ejection fraction of left ventricle. METHODS Our study was designed as a prospective case control study. We included 40 patients with persistent A...
متن کامل4D flow CMR detects progressive improvement in ventricular function following cardioversion of atrial fibrillation
Background Atrial fibrillation (AF) causes impairment of cardiac hemodynamics and substantial cardiovascular morbidity. While AF is difficult to assess with cardiac gated CMR, successful electrical cardioversion of chronic AF is often followed by a transient period of atrial stunning where absence of mechanical atrial contraction, similar to that seen in AF, persists despite reinstitution of si...
متن کاملPulsed Doppler evaluation of atrial mechanical function after electrical cardioversion of atrial fibrillation.
Full recovery of atrial mechanical activity may not occur immediately after successful electrical cardioversion of atrial fibrillation to sinus rhythm. To examine the time course of recovery of left atrial mechanical function, serial two-dimensional, M-mode and transmitral pulsed Doppler echocardiographic studies were performed in 21 patients after elective direct current cardioversion of atria...
متن کاملClinical variables affecting recovery of left atrial mechanical function after cardioversion from atrial fibrillation.
OBJECTIVES We sought to evaluate the effect of clinical factors on recovery of atrial function after cardioversion for atrial fibrillation. BACKGROUND Lack of effective mechanical atrial function (EMAF) after cardioversion of atrial fibrillation predisposes to thromboembolic complications and delays improvement in functional capacity. METHODS Fifty-two patients underwent cardioversion (grou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 87 4 شماره
صفحات -
تاریخ انتشار 2002