MERIS / ENVISAT Vicarious Calibration Results at Railroad Valley Playa (NV)*

نویسندگان

  • Mathias Kneubühler
  • Michael Schaepman
  • Kurt Thome
چکیده

On August 22, 2002, a vicarious calibration (VC) experiment of MERIS, a pushbroom imaging spectrometer on ESA’s ENVISAT, was performed. The purpose of this experiment was the acquisition of in-situ measurements of surface and atmospheric conditions over a bright, uniform target. These data were then used to compute top-ofatmosphere (TOA) radiances, which were correlated with the MERIS TOA radiances (Level 1b product), to determine the in-flight radiometric response of the on-orbit sensor. The Rail Road Valley Playa, NV, was the primary target chosen by the Optical Sciences Center, University of Arizona, and the Remote Sensing Laboratories, University of Zürich, for this experiment. The in-situ estimations of top-of-atmosphere radiances lie within less than 6% of the MERIS measurements, except for band 11 (760 nm) and band 15 (900 nm). The absolute uncertainty of the vicarious calibration experiment is estimated to be less than 3.36%. Based on the uncertainties of the vicarious calibration method and the calibration accuracies of MERIS, no recommendation to update the MERIS calibration may be given. Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: https://doi.org/10.5167/uzh-97045 Published Version Originally published at: Kneubühler, Mathias; Schaepman, Michael E; Thome, Kurt (2003). MERIS / ENVISAT Vicarious Calibration Results at Railroad Valley Playa (NV). In: 3th EARsel workshop on Imaging Spectroscopy, Herrsching, Germany, 13 May 2003 16 May 2003, 88-94. MERIS / ENVISAT Vicarious Calibration Results at Railroad Valley Playa (NV)* Mathias Kneubühler, Michael Schaepman, and Kurt Thome a Remote Sensing Laboratories (RSL),University of Zürich, Winterthurerstrasse 190, 8057 Zürich, Switzerland, kneub (schaep)@geo.unizh.ch b Optical Sciences Center, University of Arizona, 1631 E. University Boulevard, Tucson, AZ 85721 USA, [email protected]

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Meris Land Product Accuracy Assessment Based on Vicarious Calibration and Regional Validation

Since the launch of MERIS on board of ENVISAT long term activities using vicarious calibration approaches have been set in place to monitor potential drifts in the calibration of the radiance products of MERIS. In this paper, a stable and well monitored reference calibration site named Railroad Valley Playa (Nevada, USA) is used to derive the calibration uncertainties of the MERIS FR TOA radian...

متن کامل

Carbon Dioxide and Methane at a Desert Site—A Case Study at Railroad Valley Playa, Nevada, USA

Ground based in-situ measurements of carbon dioxide (CO2) and methane (CH4) at the dry lakebed at Railroad Valley (RRV) playa, Nevada, USA (38°30.234′ N, 115°41.604′ W, elevation 1437 m) were conducted over a five day period from 20–25 June 2010. The playa is a flat, desert site with virtually no vegetation, an overall size of 15 km × 15 km and is approximately 110 km south-west of the nearest ...

متن کامل

Vicarious radiometric calibration of EO-1 sensors by reference to high-reflectance ground targets

The Remote Sensing Group at the University of Arizona has been using ground targets for the in-flight vicarious calibration of airborne and satellite sensors since the early 1980s. Targets such as Railroad Valley Playa in north central Nevada and White Sands Missile Range in New Mexico have proven to be useful for this work. This paper presents the results from multiple vicarious calibration ex...

متن کامل

Cross comparison of EO-1 sensors and other Earth resources sensors to Landsat-7 ETM+ using Railroad Valley Playa

The Remote Sensing Group at the University of Arizona has used ground-based test sites for the vicarious calibration of airborne and satellite-based sensors, of which the Railroad Valley Playa in north central Nevada has played a key role. This work presents a cross comparison of five satellite-based sensors that all imaged this playa on July 16, 2001. These sensors include the Advanced Land Im...

متن کامل

Absolute radiometric calibration of Landsat 7 ETM+ using the reflectance-based method

A key to the continuation of quantitative data from the Landsat series of sensors is the radiometric understanding of the sensor. Vicarious calibration methods are one approach that has been used successfully for the absolute radiometric calibration of Thematic Mapper (TM). One of these vicarious methods is the reflectance-based approach that is applied here to the radiometric calibration of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017