Total removal of unwanted harmonic peaks (TruHARP) MRI for single breath-hold high-resolution myocardial motion and strain quantification.
نویسندگان
چکیده
Current MRI methods for myocardial motion and strain quantification have limited resolution because of Fourier space spectral peak interference. Methods have been proposed to remove this interference in order to improve resolution; however, these methods are clinically impractical due to the prolonged imaging times. In this paper, we propose total removal of unwanted harmonic peaks (TruHARP); a myocardial motion and strain quantification methodology that uses a novel single breath-hold MR image acquisition protocol. In post-processing, TruHARP separates the spectral peaks in the acquired images, enabling high-resolution motion and strain quantification. The impact of high resolution on calculated circumferential and radial strains is studied using realistic Monte Carlo simulations, and the improvement in strain maps is demonstrated in six human subjects.
منابع مشابه
Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.
The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence, a CINE sequence of images with 1-1 spatial modulation of magnetization (SPAM...
متن کاملComparison of the quantitative first pass myocardial perfusion MRI with and without prospective slice tracking: comparison between breath-hold and free-breathing condition.
Physiologic motion of the heart is one of the major problems of myocardial blood flow quantification using first pass perfusion-MRI method. To overcome these problems, a perfusion pulse sequence with prospective slice tracking was developed. Cardiac motion was monitored by a navigator directly positioned at heart's basis to overcome no additional underlying model calculations connecting diaphra...
متن کاملFree-breathing myocardial perfusion MRI using SW-CG-HYPR and motion correction.
First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-base...
متن کاملWhole-heart T1-mapping with single breath-hold
Background T1-mapping, directly measuring the underlying longitudinal relaxation times (T1), and extracellular volume (ECV) quantification, are emerging techniques for myocardial fibrosis quantification. Recent studies have reported significant T1 differences in fibrotic and normal tissue, but whole-heart T1-mapping is rarely performed in clinical practice, due to the associated time-consuming ...
متن کاملQuantification of 3D Cardiac Motion in Mice Using Multi-Phase DENSE MRI
MRI provides a valuable tool for noninvasive evaluation of myocardial wall motion. Recently, multi-phase 2D DENSE MRI was developed to quantify cardiac strain in mice at high spatial and temporal resolution [1, 2]. DENSE methods for 3D displacement encoding have also been investigated [3]. Typically, these methods entail multiple acquisitions that are time consuming. In this project, we aimed t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 2 شماره
صفحات -
تاریخ انتشار 2010