Flow-through optosensing of 1-naphthaleneacetic acid in water and apples by heavy atom induced-room temperature phosphorescence measurements.

نویسندگان

  • María Teresa Fernández-Argüelles
  • Beatriz Cañabate
  • Antonio Segura
  • José Manuel Costa
  • Rosario Pereiro
  • Alfredo Sanz-Medel
  • Alberto Fernández
چکیده

A sensitive and selective phosphorimetric method for the determination of 1-naphthaleneacetic acid (1-NAA) based on a flow-injection system connected to a flow cell packed with a solid support and placed in the sample compartment of a conventional luminescence spectrometer is described. A non-ionic solid polymeric resin Amberlite XAD-7 is used for the packing. After injection of the sample, 1-NAA is on-line retained in the packed resin and measurements of the heavy atom induced (HAI)-room temperature phosphorescence (RTP) emission (lambda(ex)/lambda(em)=292/490nm) from this native luminescent compound are taken. The optimum experimental conditions were investigated by injecting 2ml samples of an aqueous solution of 1-NAA in the flow system. A concentration 0.15moll(-1) of thallium(I) ions, as heavy atom, both in the samples and the carrier flow, was finally selected. Also, a concentration of 6mmoll(-1) of sulphite was optimal for ensuring the necessary deoxygenation of the system at the selected flow rate of 0.8mlmin(-1). After measurement, the solid support was efficiently regenerated by injecting 1ml of a mixture water:acetone in a ratio 1:1 (v/v) into the flow. The detection limit (3sigma criterion) was 1.2ngml(-1) of 1-NAA. The repeatability (R.S.D.) for five replicates of a sample containing 50ngml(-1) of analyte turned out to be +/-3% and the calibration graphs proved to be linear up to 500ngml(-1) of 1-NAA (maximum concentration assayed). The effect of potential interferences from other organic species which can be also used as plant growth regulators, as well as from various inorganic cations and anions, has been investigated as well. The method was successfully applied to the determination of low levels of this plant growth regulator in natural waters (river and fountain waters) and apples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iodinated molecularly imprinted polymer for room temperature phosphorescence optosensing of fluoranthene.

A novel molecularly imprinted polymer (MIP) of high interest for room temperature phosphorescence (RTP) sensing systems is described; the synthesized MIP contains iodine as internal heavy atom in the polymeric structure and its applicability for RTP sensing of fluoranthene at microg L(-1) levels is demonstrated.

متن کامل

Method for the Quantitative Determination of 1-Naphthaleneacetic Acid in Spiked Canned Pineapple Samples by Micelle-Stabilized Room Temperature Phosphorescence.

This paper presents a convenient method for the determination of 1-naphthaleneacetic acid (NAA) plant growth regulator in spiked canned pineapple samples by micellar-stabilized room temperature phosphorescence with sodium dodecyl sulfate as a micellar medium, thallium nitrate as an external heavy atom, and sodium sulfite as an oxygen scavenger. A multivariate optimization approach using the typ...

متن کامل

Heavy Atom Induced Room Temperature Phosphorescence Method for the Determination of the Plant Growth Regulator â-Naphthoxyacetic Acid

A simple, selective, and sensitive heavy atom induced room temperature phosphorimetric method (HAI-RTP) is described for the determination of the plant growth regulator â-naphthoxyacetic acid (NOA) in spiked apple samples. A careful selection of the different variables (heavy atom and sodium sulfite) to obtain the phosphorescence signal constitutes the basis of a HAI-RTP method for the determin...

متن کامل

Simple and rapid determination of the drug naproxen in pharmaceutical preparations by heavy atom-induced room temperature phosphorescence.

A simple, selective and sensitive heavy atom-induced room temperature phosphorimetric method (HAI-RTP) is described for the determination of naproxen (NAP) in pharmaceutical preparations. The phosphorescence signals are a consequence of intermolecular protection when analytes are, exclusively, in presence of a heavy atom salt and sodium sulfite as an oxygen scavenger to minimize RTP quenching. ...

متن کامل

Room temperature phosphorescence in the liquid state as a tool in analytical chemistry

A wide-ranging overview of room temperature phosphorescence in the liquid state (RTPL1) is presented, with a focus on recent developments. RTPL techniques like micelle-stabilized (MS)-RTP, cyclodextrin-induced (CD)-RTP, and heavy atom-induced (HAI)-RTP are discussed. These techniques are mainly applied in the stand-alone format, but coupling with some separation techniques appears to be feasibl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Talanta

دوره 66 3  شماره 

صفحات  -

تاریخ انتشار 2005