Comparison of DENSE Reference Strategies
نویسندگان
چکیده
Introduction: Magnetic resonance imaging (MRI) offers the possibility of in-vivo quantitative measurement of myocardial deformation using displacement encoding with stimulated echoes (DENSE) [1]. DENSE encodes the spatial position at a reference time in the cardiac cycle, usually at the R-wave in the ECG. Readouts are then performed later during the cardiac cycle, producing images with a phase proportional to the displacement. Several aspects need to be taken into account when designing a DENSE pulse sequence; magnetic field inhomogeneities, suppression of artifact generating echoes, displacement to noise ratio and signal attenuation due to intravoxel phase dispersion. Most DENSE acquisitions use some kind of phase reference in order to correct for various artifacts. The aim of this work is to evaluate, in-vitro and in-vivo, the influence of DENSE phase reference strategy on the accuracy of the displacement measurement. Methods: Three DENSE phase references strategies were evaluated using two phantoms and in-vivo using a 1.5T Philips Achieva MRI scanner. The strategies are referred to as “single”, “double” or “symmetric” reference (Table 1). Single reference consists of a single acquisition using zero displacement encoding gradient strength. Double reference adds a complementary acquisition of the non-displacement encoded reference acquisition, analogous to CSPAMM [2], to suppress the T1 echo. In the symmetric reference encoding scheme, the reference consists of a complementary acquisition, but with a non-zero displacement encoding. Subsequent phase subtraction then compensate for magnetic field inhomogeneities. The scan parameters were: EPI-factor 7, TFE-factor 3, TE/TR 4.9/10.6 ms, phase interval 50 ms, acquisition matrix 140×121, FOV 350×350, slice thickness 8 mm, SENSE-factor 2, displacement encoding strength of 0.35 cycles per pixel. Data were reconstructed to 2.43×2.43 mm voxels. Two flip angle regimes were evaluated, fixed 20 degree and optimized for constant SNR [2]. A phantom with a homogeneous gelatin mixture was used to evaluate the accuracy of the displacement over 100×100 voxels. Another phantom consisting of the gelatin mixture and butter was used to evaluate the effects of chemical shift in ROIs of 31×11 voxels. In-vivo measurements were preformed on a 25 year old healthy male volunteer with no previous history of cardiac disease to visually study image quality and suppression of blood signal. Results: The single reference resulted in a temporal varying offset of the displacement in all directions. A varying offset could also be seen in the double reference, but only in the through-plane component (not shown). No varying offset was seen using the symmetric reference. Measurement using symmetric reference produced a smaller standard deviation than the single and double reference, as seen in Figure 1. Figure 2 shows the difference in displacement due chemical shift. Varying difference can be seen in the single and double reference, while no severe offset can be seen with the symmetric reference. Examining the in-vivo anatomical magnitude images, no obvious artifact could be seen in the in-plane components (not shown). However, only the symmetric reference provided favorable black blood effect from the through-plane displacement, as shown in Figure 3. Discussion: The phase reference compensates for phase contribution due to magnetic field inhomogeneities. However, the phase images with zero displacement encoding do not separate the stimulated echo, the stimulated anti-echo and the T1 echo. In the beginning of the cardiac cycle, when the T1 echo is weak, the single reference produce a stimulated echo weighted result, but at the end of the cardiac cycle it mainly consists of the T1 echo, which has a different phase. This explains the varying offset in the in-plane components for the single reference method and is not seen for double reference which suppresses the T1 echo. This suppression might not be adequate in all cases, however, and the residual T1 echo will manifest at the same location as the stimulated echo in k-space. This makes it difficult to further suppress the T1 echo, e.g. by using k-space filtering [3], if the complementary acquisition is insufficient. This insufficient T1 suppression probably explains the varying offset in the through-plane component as well as the limited black blood effect for the single and double reference. Neither of these shortcomings are seen for the symmetric reference. References [1] Aletras et al, J Magn Reson 1999;137(1):247-252 [2] Fischer et al, Magn Reson Med 1993;30(2):191-200 [3] Kim et al, Radiology 2004;230(3):862-871 X-encoding Y-encoding Z-encoding Reference Single (+EX,0,0) (0,+EY,0) (0,0,+EZ) (0,0,0) Double (+EX,0,0) (0,+EY,0) (0,0,+EZ) (0,0,0) Symmetric (+Ex,-EY,-EZ) (-EX,+EY,-EZ) (-EX,-EY,+EZ) (-EX,-EY,-EZ) Table 1: Summary of the reference encodings using encoding gradientents in X (EX), Y (EY) and Z (EZ) direction.
منابع مشابه
Exploring the Patterns of Evaluative Language in Physics Blurbs: The Appraisal Strategies in Focus
The current study qualitatively examined blurbs in the discipline of physics which is perceived to be less infused with evaluative resources and more objective and impersonal in its textual argumentation. The study followed the appraisal framework proposed by Martin and White (2005) to see how interpersonal meaning is textually constructed in blurbs. Findings indicated that writers of the blurb...
متن کامل3D Classification of Urban Features Based on Integration of Structural and Spectral Information from UAV Imagery
Three-dimensional classification of urban features is one of the important tools for urban management and the basis of many analyzes in photogrammetry and remote sensing. Therefore, it is applied in many applications such as planning, urban management and disaster management. In this study, dense point clouds extracted from dense image matching is applied for classification in urban areas. Appl...
متن کاملExploring the Translator\'s Solutions to the Translation of Conversational Implicatures from English into Persian: the Case of Tolkien\'s the Lord of the Rings
The present study aimed to examine the translatorchr('39')s solutions to the translation of conversational implicatures from English into Persian. To do so, 120 conversational implicatures were extracted from the novel the Lord of the Rings (Tolkien, 1954) and classified based on Gricechr('39')s (1975) categorization of Maxims, including quality, quantity, relevance, and manner. Mur Duenaschr('...
متن کاملAn Effective 3-Dimensional Regional Myocardial Strain Computation Method with Displacement ENcoding with Stimulated Echoes (DENSE) in Dilated Cardiomyopathy Patients and Healthy Subjects
Fast Cine Displacement ENcoding with Stimulated Echoes (DENSE) is a magnetic resonance imaging (MRI) technique attributed with higher spatial resolution and rapid post-processing. Our primary goal was three-dimensional (3D) regional strains quantification using DENSE images in healthy subjects and non-ischemic, non-valvular dilated cardiomyopathy (DCM) patients, followed by validation with comp...
متن کاملQuality Assessment of Non-dense Image Correspondences
Non-dense image correspondence estimation algorithms are known for their speed, robustness and accuracy. However, current evaluation methods evaluate correspondences point-wise and consider only correspondences that are actually estimated. They cannot evaluate the fact that some algorithms might leave important scene correspondences undetected correspondences which might be vital for succeeding...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008