Temperature-dependent changes of chloride transport kinetics in human red cells
نویسنده
چکیده
Chloride self-exchange in human red cells was studied between 0 degrees C and 38 degrees C. At higher temperatures the flow-tube method was used. Although the general features of chloride transport at 0 degrees C and 38 degrees C are similar, the following differences were found: (a) the maximum pH of chloride self-exchange flux was lowered 0.6 pH unit from 7.8 to 7.2 when temperature was increased from 0 degrees C to 38 degrees C; (b)the apparent half-saturation constant increased from 28 mM at 0 degrees C to 65 mM at 38 degrees C; (c) chloride transport at body temperature is slower than predicted by other investigators by extrapolation from low-temperature results. Chloride transport increased only 200 times when temperature was raised from 0 degrees C to 38 degrees C, because the apparent activation energy decreased from 30 kcal mol(-1) to 20 kcal mol(-1) above a temperature of 15 degrees C; (d) a study of temperature dependence of the slower bromide self-exchange showed that a similar change of activation energy occurred around 25 degrees C. Both in the case of Cl(-) (15 degrees C) and in the case of Br(-) (25 degrees C), critical temperature was reached when the anion self-exchange had a turnover number of about 4x10(9) ions cell (-1)s(-1); (e) inhibition of chloride transport by DIDS (4,4'- diisothiocyano-stilbene-2,2'-disulfonate)revealed that the deflection persisted at 15 degrees C at partial inhibition (66 percent) presumably because DIDS inactivated 66 percent of the transport sites. It is suggested that a less temperature- dependent step of anion exchange becomes rate limiting at the temperature where a critical turnover number is reached.
منابع مشابه
Kinetics of chloride transport across fish red blood cell membranes
The continuous flow tube method was used to investigate the kinetics of chloride transport, and its potential oxygenation-dependency, in red blood cells (RBCs) from four teleost fish species and man. A significant interspecific variation in Cl- transport kinetics was found. At 15 °C, the rate constant k for unidirectional 36Cl- efflux was significantly lower in RBCs from eel and carp than i...
متن کاملSome effects of low pH on chloride exchange in human red blood cells
In order to test the range of pH values over which the titratable carried model for inorganic anion exchange is valid, chloride self-exchange across human red blood cells was examined between pH 4.75 and 5.7 at 0 decrees c. It was found that chloride self-exchange flux had a minimum near pH 5 and increased again with further increase in hydrogen ion activity. The Arrhenius activation energy for...
متن کاملA Fickian diffusion transport process with features of transport catalysis. Doxorubicin transport in human red blood cells
The transport of the antineoplastic drug doxorubicin (Adriamycin) in human red blood cells was investigated by measuring the net efflux from loaded cells. Previous data indicated that doxorubicin transport was a Fickian diffusion transport process of the electrically neutral molecule through the lipid domain of the cell membrane (Dalmark, 1981 [In press]). However, doxorubicin transport showed ...
متن کاملEffects of halides and bicarbonate on chloride transport in human red blood cells
Chloride self-exchange was determined by measuring the rate of 36Cl efflux from human red blood cells at pH 7.2 (0 degrees C) in the presence of fluoride, bromide, iodide, and bicarbonate. The chloride concentration was varied between 10--400 mM and the concentration of other halides and bicarbonate between 10--300 mM. Chloride equilibrium flux showed saturation kinetics. The half-saturation co...
متن کاملSurface Coating of Red Blood Cells with Monomethoxy poly(ethylene glycol) Activated with Two Different Reagents
Methoxy poly(ethylene glycol) (mPEG) with molecular mass of 5 kDa activated with succinimidyl carbonate and cyanuric chloride, separately was covalently attached to human red blood cells (RBCs). Inhibition of agglutination by blood-type specific antisera (anti-D) was employed to evaluate the effect of the polymer coating. The remaining single cells after incubation with anti-D sera were cou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of General Physiology
دوره 70 شماره
صفحات -
تاریخ انتشار 1977