PMMA Third-Body Wear after Unicondylar Knee Arthroplasty Decuples the UHMWPE Wear Particle Generation In Vitro
نویسندگان
چکیده
INTRODUCTION Overlooked polymethylmethacrylate after unicondylar knee arthroplasty can be a potential problem, since this might influence the generated wear particle size and morphology. The aim of this study was the analysis of polyethylene wear in a knee wear simulator for changes in size, morphology, and particle number after the addition of third-bodies. MATERIAL AND METHODS Fixed bearing unicondylar knee prostheses (UKA) were tested in a knee simulator for 5.0 million cycles. Following bone particles were added for 1.5 million cycles, followed by 1.5 million cycles with PMMA particles. A particle analysis by scanning electron microscopy of the lubricant after the cycles was performed. Size and morphology of the generated wear were characterized. Further, the number of particles per 1 million cycles was calculated for each group. RESULTS The particles of all groups were similar in size and shape. The number of particles in the PMMA group showed 10-fold higher values than in the bone and control group (PMMA: 10.251 × 10(12); bone: 1.145 × 10(12); control: 1.804 × 10(12)). CONCLUSION The addition of bone or PMMA particles in terms of a third-body wear results in no change of particle size and morphology. PMMA third-bodies generated tenfold elevated particle numbers. This could favor an early aseptic loosening.
منابع مشابه
Mechanical Properties and Tribological Behaviour of Retrieved UHMWPE Tibial Insert in Total Knee Replacement after Implantation 30 Months
Ultra high molecular weight polyethylene (UHMWPE) has been used as a load bearing and articulating counter face in total knee replacement (TKR) for over forty years1. However, wear debris generation of UHMWPE materials after their implantation in the human body has been proven to induce osteolysis and aseptic loosening, which is the main cause of long-term failure of TKR composed of UHMWPE and ...
متن کاملHistopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients
Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear in in vitro and animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as we...
متن کاملFailure of a metal-on-metal total hip arthroplasty from progressive osteolysis.
Ultra-high-molecular weight polyethylene (UHMWPE) wear, debris-induced osteolysis is a frequent cause of failure of total hip arthroplasty. Metal-on-metal total hip arthroplasty eliminates the generation of UHMWPE particulate debris. Although the volumetric wear of a metal-on-metal articulation may be lower than a metal-UHMWPE articulation, the number of particles may be higher. Osteolysis can ...
متن کاملReduction of Wear in Fixed Bearing Total Knee Replacement Using Crosslinked Uhmwpe
Introduction Reduction of ultra high molecular weight polyethylene (UHMWPE) surface wear in total knee replacement (TKR) bearings may delay the onset of osteolysis and subsequent loosening of components. Crosslinking has been shown to increase the wear resistance of UHMWPE bearings in multidirectional total hip replacement applications when articulating against smooth counterfaces [1]. The aim ...
متن کاملThe biological response to nanometre-sized polymer particles
Recently, nanometre-sized UHMWPE particles generated from hip and knee replacements have been identified in vitro and in vivo. UHMWPE particles in the 0.1-1.0μm size range have been shown to be more biologically active than larger particles, provoking an inflammatory response implicated in late aseptic loosening of total joint replacements. The biological activity of nanometre-sized particles h...