Indirect measurement of blood pressure during exercise testing can be misleading.

نویسندگان

  • B A Gould
  • R S Hornung
  • D G Altman
  • P M Cashman
  • E B Raftery
چکیده

Indirect blood pressures recorded with a random zero sphygmomanometer were compared with simultaneous intra-arterial blood pressures recorded with the Oxford system. Twenty five patients undertook a graded bicycle exercise test, cycling at workloads increasing from 41, 65, 114, and 163 W (250 to 400, 700, and 1000 kpm per min) with each grade being maintained for three minutes unless the exercise test was terminated earlier at the point of fatigue. Intra-arterial pressures were recorded continuously and indirect measurements made at steady state levels in the 30 seconds before each change in grade and immediately after the termination of the exercise protocol. The mean difference in systolic blood pressure at 5.5 minutes of exercise showed that the indirect measurement underestimated the direct measurement. Immediately after the termination of exercise the blood pressure fell precipitiously to a highly significant degree. For both systolic and diastolic pressures there was considerably individual variability. These data confirm that indirect methods of blood pressure measurement during dynamic exercise testing are inaccurate and may provide misleading information.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia

Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...

متن کامل

A study of variation in cardiocirculatory parameters with different body positions during isometric exercise in young adult males.

Introduction: To study the effects of exercise, how important it is to choose a posture? We aimed to characterize the possible impact of different body positions on cardiovascular parameters during and after sustained isometric handgrip (IHG) exercise. Materials and Methods: Cross sectional study was carried out in 33 young adult males (mean age: 19.21±1.083 years). We recorded Bloo...

متن کامل

Accuracy of automated auscultatory blood pressure measurement during supine exercise and treadmill stress ECG-testing

Objectives Monitoring of brachial blood pressure during exercise-ECG testing is mandatory and changes in blood pressure (BP) can provide critical management evidence. Patient movement, mechanical vibration, artifactual sounds and observer variability make standard manual techniques problematic. This was an investigator-initiated study to assess an automated auscultatory technique of BP assessme...

متن کامل

The Effect of Eucalyptus Essence Inhalation on Pulmonary Function During One bout of a Submaximal exercise in Young Girls

Background: Respiratory function is very important for athletes and can have an impact on physical performance. Inhaling aromatic essential oils can also improve physical performance by influencing pulmonary function. Objective: Hence, the current study has been done with the purpose of investigating the effect of Eucalyptus essence inhalation on pulmonary function during one bout of a submaxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 53 6  شماره 

صفحات  -

تاریخ انتشار 1985