An automated microfluidic-based immunoassay cartridge for allergen screening and other multiplexed assays.

نویسندگان

  • Lung-Wen Tai
  • Ko-Yuan Tseng
  • Shaw-Tsu Wang
  • Chao-Cheng Chiu
  • Chak Hone Kow
  • Ping Chang
  • Chichen Chen
  • Jiu-Yao Wang
  • James R Webster
چکیده

A microfluidic cartridge and system for multiplexed immunoassays is described. The passive microfluidic cartridge was composed of three layers of injection molded plastic sealed together using a thermal staking technique. Using this platform technology, a specific immunoglobulin E (IgE) panel assay was constructed. Allergen extract targets, positive and negative controls, and IgE calibration standards were immobilized within the cartridge as a microarray. A computer-controlled solenoid array provided the necessary actuation force for pumping reagents within the cartridge to perform an automated, chemiluminescent indirect immunoassay. A 20-target allergen extract panel was demonstrated on the device with a total analysis time of 27 min. Allergen screening results showed 84% agreement for 3 house dust mites (N=300) compared with a commercial test and 80% agreement overall (N=978). Average coefficients of variation (N=80) were measured as 20.5% for low/medium levels and 20.4% for medium/high levels. The average limit of detection (N=160) was measured at 0.535 AU, and cutoff levels of 1.0 AU were estimated at less than 1 IU/ml (2.4 ng/ml). Such a system has potential applications in decentralized allergen screening as well as in other near-patient diagnostic immunoassays where multiplexed analysis, ease of use, and short analysis time are critical.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of multiple allergen-specific IgE by microfluidic immunoassay cartridge in clinical settings.

Our aims were to evaluate the performance of an automated microfluidic immunoassay system for measuring allergen-specific IgE (sIgE) in sera against an established in vitro assay and to assess the system's diagnostic accuracy against objective clinical criteria for identifying sensitization to specific allergens in daily practice of allergy clinics. Using both the automated microfluidic-based i...

متن کامل

High sensitivity automated multiplexed immunoassays using photonic crystal enhanced fluorescence microfluidic system.

We demonstrate a platform that integrates photonic crystal enhanced fluorescence (PCEF) detection of a surface-based microspot fluorescent assay with a microfluidic cartridge to achieve simultaneous goals of high analytic sensitivity (single digit pg/mL), high selectivity, low sample volume, and assay automation. The PC surface, designed to provide optical resonances for the excitation waveleng...

متن کامل

Lab-on-a-chip for multiplexed biosensing of residual antibiotics in milk.

A multiplexed immunoassay-based antibiotic sensing device integrated in a lab-on-a-chip format is described. The approach is multidisciplinary and involves the convergent development of a multi-antibiotic competitive immunoassay based on sensitive wavelength interrogated optical sensor (WIOS) technology and a polymer-based self-contained microfluidic cartridge. Immunoassay solutions are pressur...

متن کامل

A Microfluidic Cartridge System for Multiplexed Clinical Analysis.

Cartridge-based microfluidics is a promising technology for clinical diagnostics. By miniaturizing the fluid-handling processes required for genomic and proteomic analyses, reagent and specimen volume is minimized along with the size of the system. We demonstrate an automated microfluidic system capable of performing six multiplexed genomic and proteomic analyses simultaneously, by means of an ...

متن کامل

Microfluidic barcode assay for antibody-based confirmatory diagnostics.

Confirmatory diagnostics offer high clinical sensitivity and specificity typically by assaying multiple disease biomarkers. Employed in clinical laboratory settings, such assays confirm a positive screening diagnostic result. These important multiplexed confirmatory assays require hours to complete. To address this performance gap, we introduce a simple 'single inlet, single outlet' microchanne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical biochemistry

دوره 391 2  شماره 

صفحات  -

تاریخ انتشار 2009