Abbott radiative energy attenuation method for quantifying ethanol evaluated and compared with gas-liquid chromatography and the Du Pont aca.

نویسندگان

  • P L Cary
  • P D Whitter
  • C A Johnson
چکیده

Quantification of ethanol by a radiative energy attenuation (REA) technique was evaluated and compared with results by gas-liquid chromatography (GLC) and by the Du Pont aca. Within-assay CVs were less than 5.5%. Between-assay CVs ranged from 1.9% to 6.0% for serum and blood controls at concentrations of 0.5, 1.0, and 2.5 g/L. We observed no cross reactivity with methanol, isopropanol, or acetone, and analytical recovery of ethanol from serum averaged 101%. For the three-method comparison we performed parallel determinations of 156 blood, 92 serum, and 54 urine samples containing a wide range of ethanol concentrations. Linear regression analysis of the REA results vs those of GLC or aca yielded the following: for serum, REA = 1.03 GLC -0.03 (r = 0.998), REA = 1.13 aca -0.04 (r = 0.999); for blood, REA = 0.97 GLC + 0.05 (r = 0.994), REA = 0.99 aca + 0.06 (r = 0.996); and for urine, REA = 1.01 GLC -0.03 (r = 0.998). We also discuss the clinical and forensic use of the REA method for ethanol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abbott TDx, Dade Stratus, and Du Pont aca automated digoxin immunoassays compared with a reference radioimmunoassay method.

Automated digoxin immunoassays with the Abbott TDx, Dade Stratus, and Du Pont aca were evaluated against an RIA similar to the Centers for Disease Control Candidate Reference Method. All three automated methods correlated poorly with the reference method. Particularly disconcerting were the falsely increased values (up to 0.6 micrograms/L) obtained by the Stratus for blank specimens. We discuss...

متن کامل

Evaluation and comparison of a radiative energy attenuation method for determining cholesterol in serum.

Determination of cholesterol by a radiative energy attenuation (REA) technique was evaluated and compared with results obtained by the Boehringer Mannheim High Performance Cholesterol Assay and the Du Pont aca. Within-assay and between-assay CVs for the REA method, for two sets of controls, were both less than 5%. We observed no interference with lipemic samples. Analytical recovery averaged 10...

متن کامل

Negative interference with the Du Pont aca method for measuring digoxin.

In response to a recent Letter (1) concerning the digoxin method in the aca Discrete Clinical Analyzer, the Dii Pont Company would like to offer the following. As in any enzyme immunoassay, the possibility existsthattheenzyme could be either activated or inhibited by drugs and (or) nonspecific substances, resulting in reported values that do not reflect true concentrations of the drug. We have ...

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

An evaluation of the Du Pont aca IV: does it meet medical needs?

A new bench-top analyzer from Du Pont, the "aca IV," was evaluated. To do so, we performed 10 different tests during an eight-week test period. The instrument is very precise (CVs less than 2%), results agree well with those obtained with the older acas (II and III), linearity is good in the clinically important ranges, and there is very little drift or carryover. From a medical-needs viewpoint...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 11  شماره 

صفحات  -

تاریخ انتشار 1984