Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.

نویسندگان

  • S S Jassim
  • S Patel
  • N Wardle
  • J Tahmassebi
  • R Middleton
  • D L Shardlow
  • A Stephen
  • J Hutchinson
  • F S Haddad
چکیده

Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt-chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and highly cross-linked polyethylene (XLPE) liner; Group B received an OxZi femoral head and XLPE liner; Group C received an OxZi femoral head and ultra-high molecular weight polyethylene (UHMWPE) liner. At five years, 368 patients had no statistically significant differences in short-form-36 (p = 0.176 mental, p = 0.756 physical), Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.847), pain scores (p = 0.458) or complications. The mean rate of linear wear was 0.028 mm/year (standard deviation (SD) 0.010) for Group A, 0.023 mm/year (SD 0.010) for Group B, and 0.09 mm/year (SD 0.045) for Group C. Penetration was significantly higher in the UHMWPE liner group compared with both XLPE liner groups (p < 0.001) but no significant difference was noted between CoCr and OxZi when articulating with XLPE (p = 0.153). In this, the largest randomised study of this bearing surface, it appears that using a XLPE acetabular liner is more important in reducing THA component wear than the choice of femoral head bearing, at mid-term follow-up. There is a non-significant trend towards lower wear, coupling OxZi rather than CoCr with XLPE but long-term analysis is required to see if this observation changes with time and becomes significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of head wear more than ten years after total hip arthroplasty: 22-mm zirconia vs. metal heads.

The present retrospective study assessed radiographs to determine socket wear in total hip arthroplasty (THA) with 22-mm zirconia or COP (Cobalt-Chrome alloy rich in Cobalt and Phosphorous) heads, and in cemented stems at more than 10 years after operation. Sockets of ultra high molecular weight polyethylene were used in each of two THA groups (13 hips each) in a clinical trial in our hospital ...

متن کامل

A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up

STUDY DESIGN This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. BACKGROUND The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatab...

متن کامل

A prospective randomised controlled trial comparing three alternative bearing surfaces in primary total hip replacement.

The ideal bearing surface for young patients undergoing total hip replacement (THR) remains controversial. We report the five-year results of a randomised controlled trial comparing the clinical and radiological outcomes of 102 THRs in 91 patients who were < 65 years of age. These patients were randomised to receive a cobalt-chrome on ultra-high-molecular-weight polyethylene, cobalt-chrome on h...

متن کامل

A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads.

We have reviewed 70 patients with bilateral simultaneous total hip arthroplasties to determine the rate of failure and to compare polyethylene wear and osteolysis between an implant with a cobalt-chrome head and Hylamer liner with that of a zirconia head and Hylamer liner. The mean thickness of the polyethylene liner was 11.0 mm (8.8 to 12.2) in the hip with a zirconia head and 10.7 mm (8.8 to ...

متن کامل

Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial.

BACKGROUND In vitro analysis has shown that oxidized zirconium on ultra-high molecular weight polyethylene has better wear properties than cobalt-chromium on ultra-high molecular weight polyethylene. The purpose of this study was to determine if oxidized zirconium femoral components performed better than cobalt-chromium in vivo and if the use of oxidized zirconium components had clinical advers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The bone & joint journal

دوره 97-B 7  شماره 

صفحات  -

تاریخ انتشار 2015