Micro-structurally detailed model of a therapeutic hydrogel injectate in a rat biventricular cardiac geometry for computational simulations.

نویسندگان

  • Mazin S Sirry
  • Neil H Davies
  • Karen Kadner
  • Laura Dubuis
  • Muhammad G Saleh
  • Ernesta M Meintjes
  • Bruce S Spottiswoode
  • Peter Zilla
  • Thomas Franz
چکیده

Biomaterial injection-based therapies have showed cautious success in restoration of cardiac function and prevention of adverse remodelling into heart failure after myocardial infarction (MI). However, the underlying mechanisms are not well understood. Computational studies utilised simplified representations of the therapeutic myocardial injectates. Wistar rats underwent experimental infarction followed by immediate injection of polyethylene glycol hydrogel in the infarct region. Hearts were explanted, cryo-sectioned and the region with the injectate histologically analysed. Histological micrographs were used to reconstruct the dispersed hydrogel injectate. Cardiac magnetic resonance imaging data from a healthy rat were used to obtain an end-diastolic biventricular geometry which was subsequently adjusted and combined with the injectate model. The computational geometry of the injectate exhibited microscopic structural details found the in situ. The combination of injectate and cardiac geometry provides realistic geometries for multiscale computational studies of intra-myocardial injectate therapies for the rat model that has been widely used for MI research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro Particles Transport and Deposition in Realistic Geometry of Human Upper Airways

Realistic geometry of human upper airways from mouth to the end of trachea was reconstructed by implementing the CT-Scan images of a male subject.   A computational model for analyzing the airflow in the airways was developed and several simulations were performed.  To capture the anisotropy of the inhaled airflow in the upper airways, the Reynolds stress transport model of turbulence was used ...

متن کامل

Electromechanical model of cardiac resynchronization in the dilated failing heart with left bundle branch block.

Experimental studies have shown that biventricular pacing can improve systolic function in the failing heart with bundle branch block. The goal of this study was to develop and validate a three-dimensional computational model of the dilated failing heart with left bundle branch block to investigate how biventricular pacing can improve systolic mechanical performance and synchrony. In an anatomi...

متن کامل

Simulation of Micro-Channel and Micro-Orifice Flow Using Lattice Boltzmann Method with Langmuir Slip Model

Because of its kinetic nature and computational advantages, the Lattice Boltzmann method (LBM) has been well accepted as a useful tool to simulate micro-scale flows. The slip boundary model plays a crucial role in the accuracy of solutions for micro-channel flow simulations. The most used slip boundary condition is the Maxwell slip model. The results of Maxwell slip model are affected by the ac...

متن کامل

Excessive volume of hydrogel injectates may compromise the efficacy for the treatment of acute myocardial infarction.

Biomaterial injectates are promising as a therapy for myocardial infarction to inhibit the adverse ventricular remodeling. The current study explored interrelated effects of injectate volume and infarct size on treatment efficacy. A finite element model of a rat heart was utilized to represent ischemic infarcts of 10%, 20%, and 38% of left ventricular wall volume and polyethylene glycol hydroge...

متن کامل

Effective Parameters in Contact Mechanic for Micro/nano Particle Manipulation Based on Atomic Force Microscopy

The effect of geometry and material of the Micro/Nano particle on contact mechanic for manipulation was studied in this work based on atomic force microscopy. Hertz contact model simulation for EpH biological micro particle with spherical, cylindrical, and circular crowned roller shape was used to investigate the effect of geometry on contact simulation process in manipulation. Then, to val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods in biomechanics and biomedical engineering

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2015