Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).

نویسندگان

  • Anthea Greenway
  • Vera Ignjatovic
  • Robyn Summerhayes
  • Fiona Newall
  • Janet Burgess
  • Lydia DeRosa
  • Paul Monagle
چکیده

Point-of-care (POC) monitoring of oral anticoagulation has been widely adopted in both paediatric and adult patients. A new POC system, the CoaguChek XS has recently been developed to measure the international normalised ratio (INR) and may offer significant advantages. The CoaguChek XS utilises a new method of electrochemical clot detection based on thrombin generation. This system has not been previously evaluated in children with reference to the laboratory gold standard, the prothrombin time using reference thromboplastin. It was the objective to compare values obtained by the CoaguChek XS system with both the venous INR and the gold standard for anticoagulant monitoring, prothrombin time with reference thromboplastin (rTF/95). To evaluate the impact of testing using the CoaguChek XS on clinical anticoagulant dosing decisions. Fifty paired venous INR and capillary CoaguChek XS results were obtained from 31 children (aged up to 16 years). The laboratory gold standard, a manual prothrombin time with reference thromboplastin (rTF/95) was additionally performed on 26 samples. Correlation between the CoaguChek XS result and the venous INR was r = 0.810. Agreement between the CoaguChek XS result and the reference INR was shown to be higher (r=0.95), in the subset analysed by this method. Correlation between the venous INR and reference INR was r=0.90. Despite changes to the methodology of testing with the CoaguChek XS POC monitoring system, the accuracy of this method when compared with both the venous INR and gold standard reference INR was satisfactory. This resulted in infrequent changes to clinical decision making regarding anticoagulation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-monitoring of oral anticoagulation therapy in children.

This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...

متن کامل

Multicentre ISI assignment and calibration of the INR measuring range of a new point-of-care system designed for home monitoring of oral anticoagulation therapy.

The new CoaguChek XS system is designed for use in patient selftesting. It is the successor of the current CoaguChek S system. The detection principle is based on the amperometric measurement of the thrombin activity initiated by starting the coagulation cascade using a human recombinant thromboplastin. This study was performed to assign the International SEnsitivity Index (ISI) to the new test...

متن کامل

Point of care monitoring of oral anticoagulant therapy in children: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio.

This paper reports the outcome of a research protocol aimed at optimising warfarin monitoring in a tertiary pediatric centre. The Thrombotest INR was the standard monitoring test employed to manage oral anticoagulant therapy in children at the Royal Children's Hospital (RCH), Melbourne. This study compares the results of this standard method to the novel CoaguChek INR monitor and the "gold stan...

متن کامل

Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.

Point-of-care INR (POC INR) meters can provide a safe and effective method for monitoring oral vitamin K antagonists (VKAs) in children. Stollery Children's Hospital has a large POC INR meter loan program for children requiring oral VKAs. Our protocol requires that POC INR results be compared to the standard laboratory INR for each child on several consecutive tests to ensure accuracy of CoaguC...

متن کامل

Accuracy of capillary whole blood international normalized ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 point-of-care analyzers.

We evaluated the accuracy of capillary whole blood international normalized ratio (INR) on the CoaguChek S (Roche Diagnostics, Indianapolis, IN), CoaguChek XS (Roche Diagnostics), and i-STAT 1 (i-STAT, East Windsor, NJ) point-of-care (POC) analyzers compared with venous plasma INRs determined by a reference laboratory method. Overall agreement between POC and laboratory plasma INR was very good...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2009