Validation of a Simplified, Portable Cardiopulmonary Gas Exchange System for Submaximal Exercise Testing

نویسندگان

  • Andrew D. Miller
  • Paul R. Woods
  • Thomas P. Olson
  • Minelle L. Hulsebus
  • Kathy A. O’Malley
  • Dean MacCarter
  • Bruce D. Johnson
چکیده

Shape Medical Systems, Inc. has developed a new miniaturized, simplified system for non-invasive cardiopulmonary gas exchange quantification and has targeted their system for submaximal clinical exercise testing in order to abbreviate testing in an expanding clinical market during a climate of escalating health care costs. The focus of the present study was to compare this new device to a validated, standardized system for measures of cardiopulmonary gas exchange. Eighteen healthy adults (10 male/8 female, age 29±7 yr, BMI 23.8±2.4 kg/m 2 ) were brought to the laboratory and instrumented with both measurement systems via in-series pneumotachs. Additionally, the Shape system included a pulse oximeter for heart rate (HR) and oxygen saturation (SaO2), while the standard system included separate 12-lead ECG and oximetry devices. The protocol included 2-min resting breathing, followed by 3-min at each of 3 workloads (50, 70, 125 watts) on a cycle ergometer. Data were collected breath-by-breath and averaged the last 30-sec of each workload. After a 15-min rest period, the pneumotach order was reversed and the study repeated. Since gas exchange data were similar (p>0.05) within a given metabolic testing system between sessions the data were pooled for comparing the Shape and Standard systems. There were no differences (p>0.05) between the systems for oxygen consumption-VO2, carbon dioxide production-VCO2, ventilation-VE, end tidal CO2-PetCO2, tidal volume-VT, respiratory rate-fb, and HR at rest or any work load. SaO2 was slightly, but significantly lower using the Shape embedded oximeter (p<0.05, averaging ~1% across workloads). There were significant correlation coefficients (p<0.001) between the systems for VO2 (r=0.991), VCO2 (r=0.986), VE (r=0.995) and PetCO2 (r=0.953). Bland Altman plots indicated good agreement between systems for the same gas exchange measures, independent of workload. The Shape system was sensitive to small increases in work (50 to 70 watts) and there were no differences in gas exchange measures in a subgroup of subjects (n=4) using a tight fitting mask instead of a mouthpiece (p>0.05). These data suggest that the new, simplified metabolic system developed by Shape Medical Systems, Inc. accurately quantifies key cardiopulmonary variables over a range of workloads, has a coefficient of variation similar to a well validated system and can be used with mouthpiece or mask.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiopulmonary exercise testing following hay exposure challenge in farmer's lung.

In patients experiencing an acute episode of hypersensitivity pneumonitis (HP), the alveoli and interstitium show a marked inflammation. The effects of this infiltration with effector cells on gas exchange and the cardiopulmonary system are not well characterized, and there are no data regarding cardiopulmonary exercise testing during hypersensitivity pneumonitis. The aim of this study was to g...

متن کامل

'Every breath you take I'll be watching you': measuring exercise kinetics during 6-min walking test in COPD.

rameters, including pulse rate, oxygen saturation (SpO 2 ), oxygen uptake (VO 2 ), carbon dioxide output (VCO 2 ), total volume, and breathing frequency, and to quantify VO 2 kinetics in real time. After carefully excluding patients with inaccurate mean response time (MRT) estimation, the authors observed that patients with more severe airflow limitation (patients with severe and very severe CO...

متن کامل

Exercise Stress Testing in Children with Metabolic or Neuromuscular Disorders

The role of exercise as a diagnostic or therapeutic tool in patients with a metabolic disease (MD) or neuromuscular disorder (NMD) is relatively underresearched. In this paper we describe the metabolic profiles during exercise in 13 children (9 boys, 4 girls, age 5-15 yrs) with a diagnosed MD or NMD. Graded cardiopulmonary exercise tests and/or a 90-min prolonged submaximal exercise test were p...

متن کامل

A primer in cardiopulmonary exercise testing.

Cardiopulmonary exercise testing is useful in diagnosing the cause of exercise intolerance, in evaluating disability, and in defining the response to therapy. This testing modality is firmly founded on physiological principles. An efficient interaction of the body's systems is required to transport oxygen to the exercising muscles; failure of any system will yield characteristic changes in the ...

متن کامل

Exogenous Ketone Supplement Ingestion And Submaximal Exercise Response in Trained, Male Cyclists: A Randomised, Double-blind Study

Background. The acute ingestion of ketone body supplements can improve exercise responses such as oxygen consumption and blood lactate. Additionally, ketone body supplements show increases in circulating βhb concentration, matching those of someone in a state of nutritional ketosis. Studies testing ketone body supplements have reported different results in exercise response and varying gastroin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010