The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans.

نویسندگان

  • Michail I Papafaklis
  • Christos V Bourantas
  • Panagiotis E Theodorakis
  • Christos S Katsouras
  • Katerina K Naka
  • Dimitrios I Fotiadis
  • Lampros K Michalis
چکیده

OBJECTIVES We aimed to explore the relationship of neointimal thickness (NT) to shear stress (SS) after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) compared with bare-metal stents (BMS). We then tested the hypothesis that drug elution attenuates the SS effect. BACKGROUND Neointimal thickness after BMS implantation has been associated with SS; pertinent data for drug-eluting stents (DES) are limited. METHODS Three-dimensional coronary artery and stent reconstruction was performed in 30 patients at 6-month follow-up after SES (n = 10), PES (n = 10), or BMS (n = 10) implantation. Baseline SS at the stent surface was calculated using computational fluid dynamics and NT at follow-up was computed in 3-dimensional space. RESULTS Neointimal thickness was lower in DES versus BMS (0.03 ± 0.07 mm vs. 0.16 ± 0.08 mm, p < 0.001) and maximum NT was reduced in SES versus PES (0.33 ± 0.13 mm vs. 0.46 ± 0.13 mm, p = 0.025). In the total population, both SS (slope: -0.05 mm/Pa, p < 0.001) and DES (coefficient for DES vs. BMS: -0.17 mm, p = 0.003) were independent predictors of NT. Subgroup analysis demonstrated a significant negative relationship of NT to SS in PES (slope: -0.05 mm/Pa, p = 0.016) and BMS (slope: -0.05 mm/Pa, p = 0.001). Sirolimus elution significantly attenuated the effect of SS on NT (interaction coefficient for SES vs. BMS: 0.04 mm/Pa, p = 0.023), whereas the SS effect remained unchanged in PES (interaction coefficient for PES vs. BMS: 0.01 mm/Pa, p = 0.71). CONCLUSIONS Neointimal thickness is significantly correlated (inversely) to SS in PES as in BMS. Sirolimus elution abrogates the SS effect on the neointimal response following stent implantation, whereas the SS effect is unchanged in PES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans

BACKGROUND In-stent hyperplasia (ISH) may develop in regions of low endothelial shear stress (ESS), but the relationship between the magnitude of low ESS, the extent of ISH, and subsequent clinical events has not been investigated. METHODS AND RESULTS We assessed the association of poststent ESS with neointimal ISH and clinical outcomes in patients treated with percutaneous coronary intervent...

متن کامل

Comparison of bare metal stent and paclitaxel-eluting stent using a novel rat aorta stent model

The purpose of our study was to create a novel rat aorta stent implantation model. Stainless steel bare metal stents (BMS) or paclitaxel-eluting stents (PES) were implanted in male Sprague-Dawley rats (BW 400 ± 20 g). Two and four weeks after stent implantation, the aorta were collected, fixed with 2% glutaraldehyde, and cut into two segments. One segment was used for scanning electron microsco...

متن کامل

Evaluation of the haemodynamic characteristics of drug-eluting stents at implantation and at follow-up.

AIMS The aim of this study was to investigate the physiologic parameters: fractional flow reserve (FFR), hyperaemic trans-stent gradient (HTG), and wall shear stress (WSS) at implantation and at 6-month follow-up in the drug-eluting sirolimus stent and in its bare metal counterpart implanted in pairs within the same patient. METHODS AND RESULTS Twenty patients, accepted for percutaneous coron...

متن کامل

Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.

BACKGROUND The safety of drug-eluting stents has been called into question by recent reports of increased stent thrombosis, myocardial infarction, and death. Such studies have been inconclusive because of their insufficient size, the use of historical controls, a limited duration of follow-up, and a lack of access to original source data. METHODS We performed a pooled analysis of data from fo...

متن کامل

Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents.

BACKGROUND Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. METHODS AND RESULTS The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 3 11  شماره 

صفحات  -

تاریخ انتشار 2010