Testing of the Repeatability of Stylus Change of Modular Probes Used in Coordinate Measuring Machines

نویسنده

  • Adam WOŹNIAK
چکیده

− In this paper, a new method of testing of the repeatability of stylus change of modular probes used in coordinate measuring machines (CMMs) is proposed. The principle of the method is presented. The validity of the method is experimentally confirmed on a bridge Zeiss ACCURA CMM by testing positioning accuracy of magnetic joins the three popular probes: TP20 (Renishaw), VAST Gold (Zeiss) and VAST XXT (Zeiss).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic error characteristics of touch trigger probes fitted to coordinate measuring machines

This paper discusses the dynamic error characteristics of touch trigger probes used with coordinate measuring machines. During the investigation, a number of important parameters have been identified, including measurement speed, probe longitude, approach distance, probe latitude, stylus length/stylus tip diameter, probe orientation, operating mode (scanning and nonscanning), scan pitch, preloa...

متن کامل

The Effect of Input Shaping on Coordinate Measuring Machine Repeatability

Coordinate Measuring Machines (CMMs) are a strategic element in the manufacture of high-precision parts because their measurements of part geometries are used for quality control and feedback on the manufacturing process. Proper CMM operation requires accurate knowledge of the position of the CMM's part sensor. The performance of a CMM is limited by background vibration levels, environmental co...

متن کامل

Performance Evaluation of Probing Systems in Data Capture for Kinematic Parameter Identification and Verification of Articulated Arm Coordinate Measuring Machines

 This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and selfcentering active probe) the accuracy and rep...

متن کامل

Probing System Characteristics in Coordinate Metrology

This paper aims at studying the effect of the dynamic errors on surface measurements using three different types of touch trigger probes attached to a bridge-type-CMM. Unforeseeable dynamic root errors of a ductile touch trigger probing system have been characterized theoretically and experimentally as well. The results were employed in validating a developed analytical twodimensional-model (2D...

متن کامل

Stylus Tip Center Position Self-Calibration Based on Invariable Distances in Light-Pen Systems

The light-pen coordinate measuring machine (LPCMM for short) is portable and flexible to measure features including invisible ones in-situ. Since different styluses are needed to measure different features and even during the process of measuring a single workpiece with complicated configurations, to improve the system measurement accuracy it is beneficial to calibrate the stylus tip center pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009