An ionised/non-ionised dual porosity model of intervertebral disc tissue.

نویسندگان

  • J M Huyghe
  • G B Houben
  • M R Drost
  • C C van Donkelaar
چکیده

The volume of the intrafibrillar water space--i.e. the water contained inside the collagen fibres--is a key parameter that is relevant to concepts of connective tissue structure and function. Confined compression and swelling experiments on annulus fibrosus samples are interpreted in terms of a dual porosity model that distinguishes between a non-ionised intrafibrillar porosity and an ionised extrafibrillar porosity. Both porosities intercommunicate and are saturated with a monovalent ionic solution, i.c. NaCl. The extrafibrillar fixed charge density of the samples is assessed using radiotracer techniques and the collagen content is evaluated by measurement of hydroxyproline concentration. The interpretation of the experimental data yields values for the intrafibrillar water content, the average activity coefficient of the ions, the Donnan osmotic coefficient, the fraction of intrafibrillar water, the stress-free deformation state, and an effective stress-strain relationship as a function of the radial position in the disc. A linear fit between the second Piola-Kirchhoff effective stress and Green-Lagrange strain yielded an effective stiffness: H(e)=1.087 +/- 0.657 MPa. The average fraction of intrafibrillar water was 1.16 g/g collagen. The results were sensitive to changes in the activity and osmotic coefficients and the fraction of intrafibrillar water. The fixed charge density increased with distance from the outer edge of the annulus, whereas the hydroxyproline decreased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evidence for ionised accretion discs in five narrow-line Seyfert 1 galaxies

We present the results of fitting ASCA spectra of six narrow-line Seyfert 1 (NLS1) galaxies with the ionised reflection models of Ross & Fabian (1993). We find that five of the galaxies (TON S 180, PKS 0558–504, Ark 564, Mrk 335 and PG 1244+026) are well fit by the ionised disc model, and these are often better fits than the alternative models considered. The sixth galaxy, NGC 4051, has additio...

متن کامل

Variable iron - line emission near the black hole of Markarian 766 ⋆

Aims. We investigate the link between ionised Fe X-ray line emission and continuum emission in a bright nearby AGN, Mrk 766. Methods. A new long (433 ks) XMM-Newton observation is analysed, together with archival data from 2000 and 2001. The contribution from ionised line emission is measured and its time variations on short (5–20 ks) timescales are correlated with the continuum emission. Resul...

متن کامل

The variable X-ray spectrum of Markarian 766 - I. Principal components analysis

Aims. We analyse a long XMM-Newton spectrum of the narrow-line Seyfert 1 galaxy Mrk 766, using the marked spectral variability on timescales > 20 ks to separate components in the X-ray spectrum. Methods. Principal components analysis is used to identify distinct emission components in the X-ray spectrum, possible alternative physical models for those components are then compared statistically. ...

متن کامل

Magnetorotational instability in stratified, weakly ionised accretion discs

We present a linear analysis of the vertical structure and growth of the magnetorotational instability in stratified, weakly ionised accretion discs, such as protostellar and quiescent dwarf novae systems. The method includes the effects of the magnetic coupling, the conductivity regime of the fluid and the strength of the magnetic field, which is initially vertical. The conductivity is treated...

متن کامل

Serum ionised calcium concentration: measurement versus calculation.

Four hundred and eighteen measurements of serum ionised calcium, total calcium, and protein concentrations were made from 47 normal volunteers, 104 patients with chronic renal failure (33 being treated conservatively and 71 with regular haemodialysis), and 83 renal transplant recipients. The serum ionised calcium concentration was measured with an Orion SS-20 meter and calculated from the total...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomechanics and modeling in mechanobiology

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2003