Sensitivity and Detection Limits of MRI, CT and SPECT for Holmium-Loaded Microspheres

نویسندگان

  • P. R. Seevinck
  • J-H. Seppenwoolde
  • T. C. de Wit
  • J. F. Nijsen
  • F. J. Beekman
  • A. D. van het Schip
  • C. J. Bakker
چکیده

P. R. Seevinck, J-H. Seppenwoolde, T. C. de Wit, J. F. Nijsen, F. J. Beekman, A. D. van het Schip, C. J. Bakker Image Sciences Institute, University Medical Center, Utrecht, Netherlands, Department of Nuclear Medicine, University Medical Center, Utrecht, Netherlands Introduction A distinct trend in image-guided treatment is the integration of imaging modalities and the development of dedicated multimodal diagnostic and therapeutic agents [1]. A therapeutic anticancer agent with multimodal imaging opportunities, viz. Holmium-loaded microspheres (HoMS), was developed by our group [2]. To investigate the possible role of this agent in the diagnostic workup and treatment of cancerous disease, more insight is needed in the performance of the agent as a multimodal diagnostic agent. HoMS has great potential as a therapeutic agent for internal radionuclide therapy of tumors since activated HoMS (Ho-166) emits high-energy βparticles. Besides that, HoMS contains the properties to become a truly multimodal diagnostic agent since it is strongly paramagnetic (MRI), has a high linear attenuation coefficient (CT) and, when activated, emits γ-rays visible with SPECT. In this work, we studied the diagnostic potential of HoMS as a multimodal contrast agent, and therefore, crucial parameters concerning low contrast detectability (sensitivity and detectability) were determined on clinical CT, MRI and SPECT scanners. Phantom experiments were conducted using straightforward clinical scan protocols and basic performance evaluation procedures. For each modality, the signal change as a function of the HoMS concentration was measured, from which the sensitivity and low contrast detectability were calculated. Materials and Methods HoMS: HoMS was prepared by solvent evaporation, resulting in a size distribution of 20-50 μm and a Holmium content of 17 % by weight. Activation for SPECT imaging was achieved by neutron bombardment, resulting in an activated fraction of 1.5 ppm Ho-166 (γ-rays: 80.6 keV (6.7%); β-particles: Emax=1.77 MeV (49%)/ 1.85 MeV (50%); t1/2=26.8h) [3]. Samples: Duplicate samples with HoMS concentrations ranging from 0 to 10 mg/ml were obtained by dissolving HoMS in a 2% agar gel. Samples were sealed in tubes with a diameter of 2.2 cm and a length of 7.0 cm. Phantom setup: Each sample was positioned co-axially in a cylindrical phantom (inner diameter 21.6 cm, inner height 18.6cm) and measured individually. Imaging parameters: MRI: Experiments were done on a 1.5 T whole-body scanner (Achieva, Philips Medical Systems, Best, NL). T2-weighted images were obtained with a multi-echo gradient-echo sequence with 15 echoes at equal intervals of 1.23ms. Other imaging parameters included: TR/TE=31/11ms; flip=25o; FOV=256x256mm; matrix=192x192; NSA=8; slice thickness=10mm; total scan time=69s. This scan protocol represents a typical T2*weighted sequence for detecting T2* modifying agents [4] CT: Experiments were done on a clinical CT scanner (Brilliance, Philips Medical Systems, Best, NL). Imaging parameters included a FOV of 350x350mm, matrix=512x512, collimation of 32x1.25mm, slice thickness of 3mm, pitch=0.671, rotation time=0.75s and total imaging time=2.82s. X-ray tube settings were 120kV and 200mAs. A soft tissue reconstruction filter was used. SPECT: Experiments were done on a clinical dual-head SPECT scanner (ADAC Vertex, Philips Medical Systems, Best, NL). A medium energy general purpose (MEGP) collimator was used. A 15% wide energy window was set around the Ho-166 photopeak at 81keV. Other imaging parameters included: matrix=128x128, projection pixel and reconstructed voxel size=4.72mm, 2 detector heads at 180o, 30 angular positions over 360o, 40 s per angle, resulting in a total scan time of 24min. No attenuation correction was applied. Reconstruction was done iteratively (n=12), using a Butterworth filter of order 5 with cut-off frequency=0.5. Data analysis: Data analysis was performed on ROI data covering the area of the sample (3.8cm). A slice thickness of 1 cm was analyzed. Calibration curves for each modality were obtained by linear regression analysis of ROI data from the reconstructed images for CT and SPECT and from the calculated R2 * maps for MRI. For MRI, CT and SPECT the signal (S) is represented by R2 * [s], CTvalue [HU] and intensity [a.u.], respectively. SPECT sensitivity is proportional to activity [Bq]. The sensitivity (dS/d[HoMS]) of each imaging modality was derived from the slope of the calibration curves. Contrast-to-noise ratios (CNR) were calculated for each modality for the ROI data relative to the background noise: CNR=(∆So/σ). The minimum HoMS concentration (Dmin) was determined using a low contrast detectability criterion of a homogeneous object of A pixels: k<CNR.sqrt(A). A detection threshold of k=5 is generally accepted [5]. Since we assume low contrast, the noise amplitude in the object and background were assumed to be equal. Results An excellent linear relationship between signal change and HoMS concentration was measured for all imaging modalities, as shown in Figure 1. SPECT turned out to yield the largest sensitivity, (316±1.9)au•ml•mg, and the highest low contrast detectability, Dmin_SPECT=0.006mg/ml. For MRI a sensitivity of (87.3±3.2)s •ml•mg was found and a low contrast detectability of Dmin_MRI=0.02mg/ml. CT appeared to have the lowest sensitivity, (6.66±0.06)HU•ml•mg , and the lowest low contrast detectability, Dmin_CT=0.12mg/ml. The temporal resolution was highest for CT with 2.8s, compared to 69s for MRI and 24min for SPECT. The results are summarized in table 1, as well as other relevant imaging parameters. Discussion and conclusions Results were obtained with standard clinical imaging protocols and reconstruction algorithms and provided a first comparison of the potential of the different imaging modalities. The experimental setup met the signal-known-exactly, background-known-exactly criteria. Different experimental setups as well as optimization procedures could lead to different outcomes. The low therapeutic activated fraction of 1.5 ppm has no influence on detectability for MRI and CT. However, a higher activated fraction would lead to a dramatic further increase in sensitivity of SPECT relative to MRI and CT. The high resolution of CT positively influenced its low contrast detectability. Furthermore, CT allowed determining high concentrations of HoMS, where MRI and SPECT met difficulties, because of fast signal decay caused by an increased relaxivity and detector saturation caused by dead-time effects, respectively. In conclusion, our phantom experiments clearly show that the presence of HoMS can be detected with three different modalities, albeit with very different sensitivity. SPECT is the most sensitive imaging modality for HoMS, but other parameters such as object size, contrast, and noise amplitude play an important role in the assessment of low contrast detectability as well. Which combination of modalities is most suitable depends on the specific task at hand, the signals from background and surrounding tissues as they occur in more realistic situations, the spatial and temporal resolution needed, and the fraction of activated Holmium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors affecting the sensitivity and detection limits of MRI, CT, and SPECT for multimodal diagnostic and therapeutic agents.

Noninvasive imaging techniques like magnetic resonance imaging (MRI), computed tomography (CT) and single photon emission computed tomography (SPECT) play an increasingly important role in the diagnostic workup and treatment of cancerous disease. In this context, a distinct trend can be observed towards the development of contrast agents and radiopharmaceuticals that open up perspectives on a m...

متن کامل

Detection and quantification of Holmium-166 loaded microspheres in patients with liver metastases: initial experience within the framework of a phase I study

Introduction: Internal radiation therapy using radioactive Holmium-166 loaded microspheres (HoMS) has shown to be a promising technique for treatment of liver metastases [1]. Unlike Yttrium-90 microspheres, which lack imaging capabilities, HoMS can be detected by Single Photon Emission Computed Tomography (SPECT) using the Holmium-166 photopeak and by MRI using the paramagnetic properties of Ho...

متن کامل

Diagnostic efficiency of 68Ga-DOTATATE PET/CT as compared to 99mTc-Octreotide SPECT/CT and conventional morphologic modalities in neuroendocrine tumors

Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...

متن کامل

Intratumoral Administration of Holmium-166 Acetylacetonate Microspheres: Antitumor Efficacy and Feasibility of Multimodality Imaging in Renal Cancer

PURPOSE The increasing incidence of small renal tumors in an aging population with comorbidities has stimulated the development of minimally invasive treatments. This study aimed to assess the efficacy and demonstrate feasibility of multimodality imaging of intratumoral administration of holmium-166 microspheres ((166)HoAcAcMS). This new technique locally ablates renal tumors through high-energ...

متن کامل

در ارزیابی سرطان سلول MRI و CT-Scan مقایسه (SCC) سنگفرشی حفره دهان

Background and purpose: Squamous Cell Carcinoma (SCC) is the most common head and neck malignancy. To decrease the side effects of treatment and the rate of mortality, careful staging for proper treatment plan is necessary. The purpose of this prospective study was to compare the diagnostic value of two different imaging methods (Computed Tomography (CT) and Magnetic Resonance Imaging (MRI)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005