Segmented photon beams technique for irradiation of postmastectomy patients.

نویسندگان

  • Anna Semaniak
  • Zbigniew Jodkiewicz
  • Anna Skowrońska-Gardas
چکیده

AIM To present the segmented photon beams technique (SPBT) for irradiation of postmastectomy patients. BACKGROUND In majority of techniques for irradiation of posmastectomy patients, a few adjacent photon or electron beams were usually implemented in order to encompass different parts of the target. In the presented SPBT technique, the radiotherapy plan consists of 6 isocentric photon beams and the area CTV includes both the chest wall and the supraclavicular area. This makes it possible to provide a uniform dose to the CTV with no hot and cold points and enables the determination of doses for the entire volume of critical organs. METHODS AND MATERIAL The treatment forward-IMRT plan comprises six isocentric 4 and 15 MV photon beams. Modulation of the dose distribution for each field was obtained by applying three segments on average. The total dose of 45 Gy was administered in 20 fractions. Dose distributions in target volume and organs at risk were evaluated for 70 randomly chosen patients. RESULTS On average, 94.8% of the CTV volume received doses within 95-107% of the prescribed dose. The average volume of the heart receiving a dose of 30 Gy and lager was 2% for patients with left breast cancer. The average dose to the lung on the irradiation side was always lower than 15.5 Gy and the average V20 Gy was below 35.5%. CONCLUSIONS The SPBT complies with requirements for high dose homogeneity within the target volume and satisfactory level of sparing of organs at risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two radiation techniques in breast boost delivery

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2012