Medical Physics International

نویسندگان

  • D. Mehta
  • R. Thompson
  • T. Morton
  • A. Dhanantwari
  • E. Shefer
چکیده

Computed Tomography (CT) scanner technology has progressed rapidly throughout the past decade, with major advances in CT x-ray detection, system speed, and image reconstruction that have resulted in a stillincreasing number of novel CT clinical applications. Concomitant to this increase in clinical applications, CT technology has also experienced innovation to support the realization of high CT image quality while adhering to the As Low As Reasonably Achievable (ALARA) principal of radiation dose management. Notable among these innovations are the introduction of modular detector designs that are optimized for low-energy, low-noise data acquisition (e.g., NanoPanel Elite, Philips Healthcare) and the introduction of CT iterative reconstruction techniques (e.g., iDose, Philips Healthcare) that manage dose, maintain image quality, and exhibit reconstruction times that fit within traditional CT workflow. The evolution to more advanced iterative reconstruction algorithms that utilize additional system information to enable further CT radiation dose reduction and image quality improvement is the next step in CT technology innovation. Although these more advanced algorithms have been used in single-photon-emission computed tomography and positron-emission tomography for some time, their use in CT was historically limited by long, clinically unacceptable, reconstruction times. Recently, IMR (Iterative Model Reconstruction, Philips Healthcare), combined with new computational hardware, has demonstrated simultaneous significant improvements in image-quality and significantly lower dose with reconstruction times of less than 5 minutes for a majority of reference protocols. Phantom tests demonstrate that IMR may simultaneously enable 60% – 80% lower radiation dose, 43% – 80% low-contrast detectability improvement, and 70% – 83% less image noise, relative to filtered back projection. Alternatively, IMR may enable 1.2x – 1.7x highcontrast spatial-resolution improvement; or 2.5x – 3.6x lowcontrast detectability improvement; or 73 90% image noise reduction, relative to filtered back projection. This article provides a review of the algorithm and its performance characteristics based on phantom studies. Keywords— Iterative Reconstruction, Knowledge-based, Model-based, IMR

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Marie Curie's contribution to Medical Physics.

On occasion of its 50th anniversary, the International Organization for Medical Physics (IOMP) from now on is going to celebrate annually an International Day of Medical Physics for which the 7th November, the birthday of Marie Sklodowska Curie, a most exceptional character in science at all and a pioneer of medical physics, has been chosen. This article briefly outlines her outstanding persona...

متن کامل

Medical physics practice and training in Ghana.

Medical physics has been an indispensable and strategic stakeholder in the delivery of radiological services to the healthcare system of Ghana. The practice has immensely supported radiation oncology and medical imaging facilities over the years, while the locally established training programme continues to produce human resource to feed these facilities. The training programme has grown to rec...

متن کامل

Influence of simultaneous-integrated boost, intensity- modulated radiation therapy on electroencephalogram records: Case report­

60-year-old woman was treated for a brain metastasis. The patient received intensity-modulated radiation therapy (SIB-IMRT) dose of 30 Gy for the whole brain and 40 Gy delivered simultaneously to individual brain metastases in 10 fractions. The present report investigated the influence of applied novel prepared treatment plan, among others the fractionation protocol on the electroencephalogram ...

متن کامل

The European Federation of Organisations for Medical Physics Policy Statement no. 15: recommended guidelines on the role of the Medical Physicist within the hospital governance board.

This EFOMP Policy Statement presents an outline on hospital governance and encourages the participation of the Medical Physicist in the hospital governance. It also emphasises how essential it is for Medical Physicists to engage in their hospital's governing board's committees for the overall good of the patient.

متن کامل

The European Federation of Organisations for Medical Physics. Policy Statement No. 7.1: The roles, responsibilities and status of the medical physicist including the criteria for the staffing levels in a Medical Physics Department approved by EFOMP Council on 5th February 2016.

This EFOMP Policy Statement is an amalgamation and an update of the EFOMP Policy Statements No. 2, 4 and 7. It presents guidelines for the roles, responsibilities and status of the medical physicist together with recommended minimum staffing levels. These recommendations take into account the ever-increasing demands for competence, patient safety, specialisation and cost effectiveness of modern...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013